首页> 美国卫生研究院文献>Journal of International Oral Health : JIOH >Tensile and shear bond strength of hard and softdenture relining materials to the conventional heat cured acrylicdenture base resin: An In-vitro study
【2h】

Tensile and shear bond strength of hard and softdenture relining materials to the conventional heat cured acrylicdenture base resin: An In-vitro study

机译:硬和软的拉伸和剪切粘结强度义齿衬里材料制成传统的热固化丙烯酸义齿基料树脂:一项体外研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delamination of the lining material. To investigate tensile and shear bond strength of 4 different commercially available denture relining materials to conventional heat cured acrylic denture base resin. >Materials & Methods: 4 mm sections in the middle of 160 Acrylic cylindrical specimens (20 mm x 8 mm) were removed, packed with test materials (Mollosil, G C Reline Soft, G C Reline Hard (Kooliner) and Ufi Gel Hard and polymerized. Specimens were divided into 8 groups of 20 each.Tensile and shear bond strength to the conventional heat curedacrylic denture base resin were examined by Instron UniversalTensile Testing Machine using the equation F=N/A (F-maximum forceexerted on the specimen (Newton) and A-bonding area= 50.24 mm2).One-way ANOVA was used for multiple group comparisons followed byBonferroni Test and Hsu’s MCB for multiple pairwise comparisons toasses any significant differences between the groups.>Results:The highest mean Tensile bond strength value was obtained for UfiGel Hard (6.49+0.08 MPa) and lowest for G C Reline Soft (0.52+0.01MPa). The highest mean Shear bond strength value was obtained forUfi Gel Hard (16.19+0.1 MPa) and lowest for Mollosil (0.59+0.05MPa). The Benferroni test showed a significant difference in themean tensile bond strength and the mean shear bond strength whenthe two denture soft liners were compared as well as when the twodenture hard liners were compared. Hsu’s MCB implied that Ufi gelhard is better than its other closest competitors.>Conclusion:The Tensile and Shear bond strength values of denture soft relinerswere significantly lower than denture hard reliners.>How to cite the article:Lau M, Amarnath GS, Muddugangadhar BC, Swetha MU, Das KA. Tensileand shear bond strength of hard and soft denture relining materialsto the conventional heat cured acrylic denture base resin: AnIn-vitro study. J Int Oral Health 2014;6(2):55-61.
机译:>背景:功能期间高应力集中可能会对义齿承载组织的状况产生不利影响。椅旁假牙(硬和软)衬板用于在功能期间分配施加到软组织的力。拉伸和剪切粘合强度已显示取决于它们的化学组成。薄弱的结合会掩盖细菌,促进衬里材料的沾污和分层。为了研究四种不同的可商购义齿衬里材料对常规热固化丙烯酸义齿基托树脂的拉伸和剪切粘合强度。 >材料与方法:取出160个丙烯酸圆柱状样品(20毫米x 8毫米)中间的4毫米切片,并装入测试材料(Mollosil,GC Reline Soft,GC Reline Hard(Kooliner)和Ufi Gel Hard和聚合后的样品分为8组,每组20个。拉伸和剪切粘合强度与常规热固化Instron Universal检查了丙烯酸义齿基托树脂使用公式F = N / A(F-最大力施加在样品上(牛顿),A结合面积= 50.24 mm2)。单向方差分析用于多组比较,然后进行Bonferroni测试和Hsu的MCB,用于与多个配对比较评估组之间的任何显着差异。>结果:获得了Ufi的最高平均抗拉强度凝胶硬(6.49 + 0.08 MPa),最低的G C Reline Soft(0.52 + 0.01)MPa)。获得了最高的平均剪切粘结强度值Ufi Gel Hard(16.19 + 0.1 MPa)和最低的Mollosil(0.59 + 0.05)MPa)。 Benferroni检验显示出时的平均拉伸粘结强度和平均剪切粘结强度比较两种义齿软衬以及两种情况比较了假牙硬衬。许的MCB暗示Ufi凝胶努力胜于其他最接近的竞争对手。>结论:义齿软衬的拉伸和剪切粘结强度值远低于义齿硬衬。>如何引用该文章:Lau M,Amarnath GS,Muddugangadhar BC,Swetha MU,Das KA。拉力硬质和软质义齿衬里材料的剪切粘合强度常规的热固化丙烯酸义齿基托树脂:体外研究。国际口腔卫生杂志2014; 6(2):55-61。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号