Construction and use of a zebrafish heart voltage and calcium optical mapping system with integrated electrocardiogram and programmable electrical stimulation

机译:具有集成心电图和可编程电刺激功能的斑马鱼心电压和钙光学测绘系统的构建和使用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Zebrafish are increasingly being used as a model of vertebrate cardiology due to mammalian-like cardiac properties in many respects. The size and fecundity of zebrafish make them suitable for large-scale genetic and pharmacological screening. In larger mammalian hearts, optical mapping is often used to investigate the interplay between voltage and calcium dynamics and to investigate their respective roles in arrhythmogenesis. This report outlines the construction of an optical mapping system for use with zebrafish hearts, using the voltage-sensitive dye RH 237 and the calcium indicator dye Rhod-2 using two industrial-level CCD cameras. With the use of economical cameras and a common 532-nm diode laser for excitation, the rate dependence of voltage and calcium dynamics within the atrial and ventricular compartments can be simultaneously determined. At 140 beats/min, the atrial action potential duration was 36 ms and the transient duration was 53 ms. With the use of a programmable electrical stimulator, a shallow rate dependence of 3 and 4 ms per 100 beats/min was observed, respectively. In the ventricle the action potential duration was 109 ms and the transient duration was 124 ms, with a steeper rate dependence of 12 and 16 ms per 100 beats/min. Synchronous electrocardiograms and optical mapping recordings were recorded, in which the P-wave aligns with the atrial voltage peak and R-wave aligns with the ventricular peak. A simple optical pathway and imaging chamber are detailed along with schematics for the in-house construction of the electrocardiogram amplifier and electrical stimulator. Laboratory procedures necessary for zebrafish heart isolation, cannulation, and loading are also presented.
机译:由于在许多方面具有类哺乳动物的心脏特性,斑马鱼正越来越多地被用作脊椎动物心脏病学的模型。斑马鱼的大小和繁殖力使其适合大规模遗传和药理筛选。在较大的哺乳动物心脏中,光学映射通常用于研究电压和钙动力学之间的相互作用,并研究它们在心律失常中的各自作用。该报告概述了用于斑马鱼心脏的光学测绘系统的构建,该系统使用了压敏染料RH 237和钙指示剂Rhod-2,并使用了两个工业级CCD相机。通过使用经济的照相机和普通的532 nm二极管激光器进行激发,可以同时确定心房和心室腔内电压和钙动力学的速率依赖性。以140次/分钟的速度,心房动作电位持续时间为36毫秒,瞬态持续时间为53毫秒。使用可编程的电刺激器,每100次心跳/分钟分别观察到3和4 ms的较慢速率依赖性。在心室中,动作电位持续时间为109毫秒,瞬态持续时间为124毫秒,每100次搏动/分钟的速率依赖性更强,分别为12和16毫秒。记录同步心电图和光学映射记录,其中P波与心房电压峰值对齐,R波与心室峰值对齐。详细介绍了一个简单的光路和成像室,以及内部构造心电图放大器和电刺激器的示意图。还介绍了斑马鱼心脏隔离,插管和加载所必需的实验室程序。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号