摘要

Burns in the neonatal period are rare and most commonly due to iatrogenic causes. We report a case of a preterm neonate who sustained a full thickness electrical burn following the use of a temporary pacing pad. The case was complicated by significant co-morbidities and the need for cardiac surgery. We describe the surgical management of the case, using excision and closure in the form of a W-plasty. We discuss the reasons for this surgical decision and the importance of managing complex cases such as this on an individual basis.
机译:新生儿时期的烧伤很少见,最常见的是由于医源性原因。我们报告了一例早产儿,在使用临时起搏垫后持续全厚度的电灼伤。该病例因大量合并症和需要心脏手术而变得复杂。我们以W型成形术的切除和闭合描述病例的外科治疗。我们讨论了做出这种外科手术决定的原因,以及根据个人情况处理此类复杂病例的重要性。