Although the incidence of cuff induced tracheal damage has been considerably reduced by judicious use of tracheal tubes with large-volume, low-pressure cuffs, aspiration continues to be a major problem. A study was conducted to determine the maximum hydrostatic pressure that can be produced by a column of liquid above the tracheal cuff. The vertical and horizontal distance between the upper central incisor teeth and suprasternal notch was measured in 200 supine adult subjects. The maximum vertical and horizontal distance between the upper central incisor teeth and suprasternal notch was 9 cm and 21 cm respectively. The implication of these findings are discussed and it is suggested that a fixed intracuff pressure in the range of 2.5 to 3kPa should be used to obtain an optimal tracheal seal.
机译:尽管通过明智地使用带有大容量低压袖带的气管导管已大大降低了袖带引起的气管损伤的发生率,但抽吸仍是一个主要问题。进行了一项研究,以确定气管袖带上方一列液体可能产生的最大静水压力。在200名仰卧成年受试者中测量了上中切牙和上胸骨切迹之间的垂直和水平距离。上中切牙和胸骨上切迹之间的最大垂直和水平距离分别为9 cm和21 cm。讨论了这些发现的含义,建议应使用2.5到3kPa的固定袖带内压力来获得最佳的气管密封。