Measurement of three dimensional shoulder movement patterns with an electromagnetic tracking device in patients with a frozen shoulder

机译:使用电磁跟踪装置测量肩周炎患者的三维肩部运动模式

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective: To compare three dimensional movement patterns of the affected and non-affected shoulder in patients with a frozen shoulder before and after physical therapy. Methods: Patients with a unilateral frozen shoulder were assessed before and after three months of treatment. Three dimensional movement analysis was performed with the "Flock of Birds" electromagnetic tracking device while the patient raised their arms in three directions. Slopes of the regression lines of glenohumeral joint rotation versus scapular rotation, reflecting the scapulohumeral rhythm, were calculated. All assessments were made for both the affected and the unaffected side. Additional assessments included conventional range of motion (ROM) measurements and visual analogue scales (VAS) (0–100 mm) for shoulder pain at rest, during movement, and at night. Results: Ten patients with a unilateral frozen shoulder were included. The slopes of the curves of the forward flexion, scapular abduction, and abduction in the frontal plane of the affected and the unaffected side were significantly different in all three movement directions. Mean differences were 0.267, 0.215, and 0.464 (all p values <0.005), respectively. Mean changes of the slopes of the affected side after treatment were 0.063 (p=0.202), 0.048 (p=0.169), and 0.264 (p=0.008) in forward flexion, scapular abduction, and abduction in the frontal plane, respectively. All patients showed significant improvement in active ROM (all p<0.005), and the VAS for pain during movement and pain at night (p<0.05). Conclusions: With a three dimensional electromagnetic tracking system the abnormal movement pattern of a frozen shoulder, characterised by the relatively early laterorotation of the scapula in relation to glenohumeral rotation during shoulder elevation, can be described and quantified. Moreover, the system is sufficiently sensitive to detect clinical improvements. Its value in other shoulder disorders remains to be established.
机译:目的:比较物理治疗前后肩周炎患者患病和未患病肩膀的三维运动模式。方法:治疗三个月前后对单侧肩周炎患者进行评估。当患者在三个方向举起手臂时,使用“鸟群”电磁跟踪设备进行了三维运动分析。计算了肩肱旋转相对于肩cap旋转的回归线的斜率,反映了肩肱节律。对患侧和未患侧均进行了所有评估。其他评估包括常规的运动范围(ROM)测量和视觉模拟量表(VAS)(0–100 mm),用于静止,运动和夜间的肩膀疼痛。结果:包括10例单侧冻结肩的患者。在所有三个运动方向上,患侧和未患侧的前平面中前屈,肩cap骨外展和外展的曲线斜率均显着不同。平均差异分别为0.267、0.215和0.464(所有p值<0.005)。治疗后患侧斜率在前屈,肩cap骨外展和额骨外展中的平均变化分别为0.063(p = 0.202),0.048(p = 0.169)和0.264(p = 0.008)。所有患者的活动性ROM均显着改善(所有p <0.005),运动中疼痛和夜间疼痛的VAS均有明显改善(p <0.05)。结论:利用三维电磁跟踪系统,可以描述和量化冻结肩部的异常运动模式,其特征是肩later骨相对于肩肱抬高旋转时肩later骨相对较早地重新定型。而且,该系统对检测临床改善足够敏感。它在其他肩部疾病中的价值仍有待确定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号