首页> 美国卫生研究院文献>Applied and Environmental Microbiology >Possible Overestimation of Surface Disinfection Efficiency by Assessment Methods Based on Liquid Sampling Procedures as Demonstrated by In Situ Quantification of Spore Viability
【2h】

Possible Overestimation of Surface Disinfection Efficiency by Assessment Methods Based on Liquid Sampling Procedures as Demonstrated by In Situ Quantification of Spore Viability

机译:通过孢子存活力的原位定量分析表明基于液体采样程序的评估方法可能高估了表面消毒效率

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The standard test methods used to assess the efficiency of a disinfectant applied to surfaces are often based on counting the microbial survivors sampled in a liquid, but total cell removal from surfaces is seldom achieved. One might therefore wonder whether evaluations of microbial survivors in liquid-sampled cells are representative of the levels of survivors in whole populations. The present study was thus designed to determine the “damaged/undamaged” status induced by a peracetic acid disinfection for Bacillus atrophaeus spores deposited on glass coupons directly on this substrate and to compare it to the status of spores collected in liquid by a sampling procedure. The method utilized to assess the viability of both surface-associated and liquid-sampled spores included fluorescence labeling with a combination of Syto 61 and Chemchrome V6 dyes and quantifications by analyzing the images acquired by confocal laser scanning microscopy. The principal result of the study was that the viability of spores sampled in the liquid was found to be poorer than that of surface-associated spores. For example, after 2 min of peracetic acid disinfection, less than 17% ± 5% of viable cells were detected among liquid-sampled cells compared to 79% ± 5% or 47% ± 4%, respectively, when the viability was evaluated on the surface after or without the sampling procedure. Moreover, assessments of the survivors collected in the liquid phase, evaluated using the microscopic method and standard plate counts, were well correlated. Evaluations based on the determination of survivors among the liquid-sampled cells can thus overestimate the efficiency of surface disinfection procedures.
机译:用于评估施加到表面的消毒剂效率的标准测试方法通常基于对液体中采样的微生物幸存者进行计数,但很少能从表面完全去除细胞。因此,人们可能会怀疑,液体采样细胞中微生物存活者的评估是否代表了整个人群中存活者的水平。因此,本研究旨在确定过乙酸消毒对直接沉积在该基质上的玻璃样片上的萎缩芽孢杆菌孢子的“损伤/未损伤”状态,并将其与通过采样程序收集到液体中的孢子的状态进行比较。用于评估表面相关孢子和液体采样孢子活力的方法包括用Syto 61和Chemchrome V6染料组合进行荧光标记,并通过分析通过共聚焦激光扫描显微镜获得的图像进行定量。该研究的主要结果是,发现在液体中采样的孢子的活力比与表面结合的孢子的活力差。例如,在过氧乙酸消毒2分钟后,在液体采样的细胞中检测不到少于17%±5%的活细胞,而当评估其活力时分别为79%±5%或47%±4%。在进行或不进行采样程序后的表面。此外,液相收集的幸存者的评估,使用显微镜方法和标准板数评估,具有很好的相关性。因此,基于确定液体采样细胞中存活者的评估可能会高估表面消毒程序的效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号