The streptozyme test was compared with the antistreptolysin O (ASO), antideoxyribonuclease B (ADN-B), and antihyaluronidase (AH) tests. One hundred and twenty-seven human serum specimens were tested by each of the four tests. The streptozyme test detected more specimens with elevated titers than any single test; however, it was not as effective as the combination of the ASO and ADN-B tests. The streptozyme test appears to be particularly useful for laboratories which rely solely on the ASO test for serological evidence of a streptococcal infection. The test can be used in these laboratories to screen all specimens with low ASO titers (<170) for the detection of ADN, AH, antinicotinamide adenine dinucleotidase, and antistreptokinase.
机译:将链酶测试与抗链球菌溶血素O(ASO),抗脱氧核糖核酸酶B(ADN-B)和抗透明质酸酶(AH)进行了比较。通过四个测试中的每个测试了一百二十七个人的血清标本。链酶测试检测到的滴度更高的标本比任何单个测试都多。但是,它不如ASO和ADN-B测试的组合有效。对于仅依靠ASO测试获得链球菌感染的血清学证据的实验室,链酶测试似乎特别有用。该测试可用于这些实验室,以筛查所有ASO滴度较低(<170)的标本,以检测ADN,AH,抗烟碱腺嘌呤二核苷酸酶和抗链激酶。