首页> 美国卫生研究院文献>Archives of Disease in Childhood. Fetal and Neonatal Edition >Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks
【2h】

Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks

机译:新生儿复苏2:评估手动通气设备和口罩

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: The key to successful neonatal resuscitation is effective ventilation. Little evidence exists to guide clinicians in their choice of manual ventilation device or face mask. The expiratory tidal volume measured at the mask (VTE(mask)) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. >Aim: To compare the efficacy of (a) the Laerdal infant resuscitator and the Neopuff infant resuscitator, used with (b) round and anatomically shaped masks in a model of neonatal resuscitation. >Methods: Thirty four participants gave positive pressure ventilation to a mannequin at specified pressures with each of the four device-mask combinations. Flow, inspiratory tidal volume at the face mask (VTI(mask)), VTE(mask), and airway pressure were recorded. Leakage from the mask was calculated from VTI(mask) and VTE(mask). >Results: A total of 10 780 inflations were recorded and analysed. Peak inspiratory pressure targets were achieved equally with the Laerdal and Neopuff resuscitators. Positive end expiratory pressure was delivered with the Neopuff but not the Laerdal device. Despite similar peak pressures, VTE(mask) varied widely. Mask leakage was large for each combination of device and mask. There were no differences between the masks. >Conclusion: During face mask ventilation of a neonatal resuscitation mannequin, there are large leaks around the face mask. Airway pressure is a poor proxy for volume delivered during positive pressure ventilation through a mask.
机译:>背景:成功进行新生儿复苏的关键是有效的通气。几乎没有证据可以指导临床医生选择手动通风设备或面罩。在面罩(VTE(mask))处测得的呼气潮气量是对模拟新生儿复苏期间输送的潮气量的良好估计。 >目标:在新生儿复苏模型中,比较(a)Laerdal婴儿复苏器和Neopuff婴儿复苏器(与(b)圆形和解剖形状的口罩一起使用)的功效。 >方法:三十四名参与者使用四种设备-面罩组合中的每一种在指定压力下对人体模型进行正压通气。记录流量,面罩(VTI(面罩)),VTE(面罩)处的吸气潮气量和气道压力。根据VTI(掩模)和VTE(掩模)计算出掩模的泄漏量。 >结果:记录并分析了10 780次通货膨胀。 Laerdal和Neopuff复苏器同样达到了峰值吸气压力目标。正末呼气压力通过Neopuff而非Laerdal装置递送。尽管有相似的峰值压力,但VTE(面罩)变化很大。器件和掩模的每种组合的掩模泄漏量都很大。口罩之间没有差异。 >结论:新生儿复苏模型的面罩通气期间,面罩周围有大量泄漏。气道压力不能很好地代表正压通气时通过面罩输送的容积。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号