首页> 美国卫生研究院文献>Journal of Ophthalmology >Autorefraction Retinoscopy Javals Rule and Grosvenors Modified Javals Rule: The Best Predictor of Refractive Astigmatism
【2h】

Autorefraction Retinoscopy Javals Rule and Grosvenors Modified Javals Rule: The Best Predictor of Refractive Astigmatism

机译:自动验光检影Javal规则和Grosvenor修正的Javal规则:屈光散光的最佳预测因子

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of the study was to determine the level of agreement between Javal's rule, autorefraction, retinoscopy, and refractive astigmatism and to determine which technique is the most suitable substitute when subjective refraction is not applicable using a clinical sample. A total of 36 subjects, 14 males and 22 females, were involved in this study. The intraclass correlation coefficients between subjective refraction, autorefraction, and retinoscopy were 0.895 and 0.989, respectively, for the spherical equivalent. The Bland-Altman 95% limits of agreement between subjective refraction and autorefraction; subjective refraction and retinoscopy; and autorefraction and retinoscopy were −2.84 to 3.58, −0.88 to 1.12, and −3.01 to 3.53, respectively, for the spherical equivalent. The intraclass correlation coefficients between spectacle total astigmatism and the following techniques were as follows: retinoscopy (0.85); autorefraction (0.92); Javal's rule (0.82); and Grosvenor et al. version (0.85). The Bland-Altman 95% limits of agreement between subjective refraction and autorefraction; subjective refraction and retinoscopy; subjective refraction and Javal's rule; and subjective refraction and Grosvenor et al. version were −0.87 to 1.25, −1.49 to 1.99, −0.73 to 1.93, and −0.89 to 1.7, respectively, for the total astigmatism. The study showed that autorefraction and Javal's rule may provide a starting point for subjective refraction cylinder power determination but only retinoscopy may satisfactorily replace subjective refraction total astigmatism when subjective refraction is not applicable.
机译:该研究的目的是确定Javal规则,自动验光,检影和屈光散光之间的一致性水平,并确定当不适用于临床样本的主观验光时哪种技术最适合替代。共有36位受试者,其中14位男性和22位女性参与了这项研究。对于球面等效物,主观验光,自动验光和检影之间的类内相关系数分别为0.895和0.989。主观屈光与自体屈光之间一致性的Bland-Altman 95%限制;主观验光和检影;对于球形当量,自折射和检影分别为-2.84至3.58,-0.88至1.12和-3.01至3.53。眼镜总散光与以下技术之间的类内相关系数如下:检影(0.85);自折射(0.92); Javal规则(0.82);和格罗夫纳等。版本(0.85)。主观屈光与自体屈光之间一致性的Bland-Altman 95%限制;主观验光和检影;主观折射和Javal规则;和主观折射和格罗夫纳等。总散光的版本分别为-0.87至1.25,-1.49至1.99,-0.73至1.93和-0.89至1.7。研究表明,自动屈光和Javal规则可能为确定主屈光度数提供了一个起点,但是当主观屈光不适用时,只有检影镜可以令人满意地替代主屈光总散光。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号