The aim of this paper was to evaluate the usefulness of the sol-gel method application, to modificate the surface of the Ti6Al7Nb alloy and the cpTi titanium (Grade 4) with SiO2 oxide, applied on the vascular implants to improve their hemocompatibility. Mechanical treatment was followed by film deposition on surface of the titanium samples. An appropriate selection of the process parameters was verified in the studies of corrosion, using potentiodynamic and impedance method. A test was conducted in the solution simulating blood vessels environment, in simulated body fluid at t = 37.0 ± 1 °C and pH = 7.0 ± 0.2. Results showed varied electrochemical properties of the SiO2 film, depending on its deposition parameters. Correlations between corrosion resistance and layer adhesion to the substrate were observed, depending on annealing temperature.
机译:本文的目的是评估溶胶-凝胶法应用的有用性,用SiO2氧化物修饰Ti6Al7Nb合金和cpTi钛(4级)的表面,将其应用于血管植入物以改善其血液相容性。机械处理之后,将膜沉积在钛样品的表面上。在腐蚀研究中,使用电位动力学和阻抗法验证了工艺参数的适当选择。在溶液模拟血管环境中,在t = 37.0±1°C和pH = 7.0±0.2的模拟体液中进行了测试。结果表明,取决于其沉积参数,SiO2膜具有不同的电化学性能。根据退火温度,观察到了耐腐蚀性和层与基材的粘附性之间的相关性。