Smoke inhalation injury is frequently accompanied by cyanide poisoning that may result in substantial morbidity and mortality, and methods are needed to quantitatively determine extent of airway injury. We utilized a 3-D endoscopic frequency-domain optical coherence tomography (FD-OCT) constructed with a swept-source laser to investigate morphological airway changes following smoke and cyanide exposure in rabbits. The thickness of the mucosal area between the epithelium and cartilage in the airway was measured and quantified. 3-D endoscopic FD-OCT was able to detect significant increases in the thickness of the tracheal walls of the rabbit beginning almost immediately after smoke inhalation injuries which were similar to those with combined smoke and cyanide poisoning.
机译:烟雾吸入损伤经常伴有氰化物中毒,可能导致大量发病和死亡,因此需要定量确定气道损伤程度的方法。我们利用3-D内窥镜频域光学相干断层扫描(FD-OCT),用扫频激光构建,以研究家兔烟雾和氰化物暴露后的形态学气道变化。测量并量化气道上皮和软骨之间的粘膜区域的厚度。 3-D内窥镜FD-OCT能够检测到吸入烟后几乎立即开始的兔气管壁厚度显着增加,这类似于烟和氰化物中毒的情况。