BackgroundDislocation remains a difficult problem in total hip arthroplasty. Large-diameter femoral heads may lower the incidence of dislocation by enhancing the jump distance and decreasing impingement, but their performance against small-diameter heads has not been assessed. This study compared the mid-term radiographic and functional outcomes of two matched cohorts of patients undergoing total hip arthroplasty who had a high pre-operative risk for dislocation and who received either small-diameter (26- or 28-millimeters) or large-diameter (≥36-millimeters) femoral heads.
机译:背景脱位仍然是全髋关节置换术中的难题。大直径的股骨头可通过增加跳跃距离和减少撞击来降低脱位的发生率,但尚未评估其对小直径股骨头的性能。这项研究比较了两组匹配的全髋关节置换术患者的中期影像学和功能结局,这些患者术前有高位错位风险,并且接受小直径(26或28毫米)或大直径(≥36毫米)股骨头。