首页> 美国卫生研究院文献>The British Journal of Ophthalmology >Ocular pulse amplitude in patients with open angle glaucoma normal tension glaucoma and ocular hypertension
【2h】

Ocular pulse amplitude in patients with open angle glaucoma normal tension glaucoma and ocular hypertension

机译:开角型青光眼正常青光眼和高眼压患者的眼搏振幅

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background/aim: Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open angle glaucoma (POAG) and high IOP, normal tension glaucoma (NTG), and ocular hypertension (OHT). Furthermore, the authors examined whether there were any correlations with blood pressure.>Methods: 80 subjects were divided into four groups (n=20): 20 patients each with POAG, NTG, and OHT and 20 volunteers without any ocular pathology except for cataract served as a control group.>Results: The OPA of the POAG group was not statistically significant different from the control group and from the OHT group. However, OPA was statistically significant lower (p<0.01) in the NTG group compared with all other groups. The OPA of the OHT group was slightly higher compared to the healthy volunteers (p=0.09) and to the POAG patients (p=0.09). No statistically significant correlations with blood pressure could be detected. A logistic regression model was established which identified OPA as an independent risk factor for NTG.>Conclusions: The study demonstrated a decrease in OPA of patients suffering from NTG. Thus, measuring of OPA by the SmartLens dynamic observing tonometer could be helpful in the detection of NTG patients.
机译:>背景/目的:眼内压(IOP)不是固定的恒定值,而是具有与心脏动作相关的搏动成分。 SmartLens动态观测眼压计(odc,由瑞士苏黎世的Ophthalmic Development Company AG生产​​)可以同时测量和记录IOP和眼动幅度(OPA)。这项研究的目的是评估原发性开角型青光眼(POAG)和高IOP,正常张力性青光眼(NTG)和高眼压(OHT)患者的OPA。此外,作者还检查了与血压之间是否存在任何相关性。>方法:将80位受试者分为四组(n = 20):20位患者分别患有POAG,NTG和OHT,20位志愿者没有血压。除白内障外,所有眼部病理均作为对照组。>结果: POAG组的OPA与对照组和OHT组在统计学上无显着差异。然而,与所有其他组相比,NTG组的OPA统计学上显着降低(p <0.01)。与健康志愿者(p = 0.09)和POAG患者(p = 0.09)相比,OHT组的OPA略高。与血压没有统计学上的显着相关性。建立了逻辑回归模型,确定OPA是NTG的独立危险因素。>结论:该研究表明,患有NTG的患者OPA降低。因此,通过SmartLens动态观察眼压计测量OPA有助于检测NTG患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号