BACKGROUND/AIM—Scleral search coils are used to measure eye movements. A recent abstract suggests that the coil can affect the eye by decreasing visual acuity, increasing intraocular pressure, and damaging the corneal and conjunctival surface. Such findings, if repeated in all subjects, would cast doubt on the credibility of the search coil as a reliable investigative technique. The aim of this study was to reassess the effect of the scleral search coil on visual function.
METHODS—Six volunteer subjects were selected to undergo coil wear and baseline measurements were taken of logMAR visual acuity, non-contact tonometry, keratometry, and slit lamp examination. Four drops of 0.4% benoxinate hydrochloride were instilled before insertion of the lens by an experienced clinician. The lens then remained on the eye for 30 minutes. Measurements of the four ocular health parameters were repeated after 15 and 30 minutes of lens wear. The lens was then removed and the health of the eye reassessed.
RESULTS—No obvious pattern of change was found in logMAR visual acuity, keratometry, or intraocular pressure. The lens did produce changes to the conjunctival and corneal surfaces, but this was not considered clinically significant.
CONCLUSION—Search coils do not appear to cause any significant effects on visual function. However, thorough prescreening of subjects and post-wear checks should be carried out on all coil wearers to ensure no adverse effects have been caused.

机译:背景技术/目标—巩膜搜索线圈用于测量眼睛的运动。最近的摘要表明,线圈可以通过降低视敏度,增加眼内压以及损坏角膜和结膜表面来影响眼睛。如果在所有主题中都重复这些发现,将会使搜索线圈作为一种可靠的调查技术的可信度产生怀疑。这项研究的目的是重新评估巩膜搜索线圈对视觉功能的影响。
方法-选择六名志愿者受试者进行线圈磨损,并进行logMAR视敏度,非接触眼压计,角膜曲率计的基线测量,并检查裂隙灯。由经验丰富的临床医生在插入晶状体之前滴入四滴0.4%的苯甲酸酯盐酸盐。然后,镜片在眼睛上停留30分钟。配戴15分钟和30分钟后,重复测量四个眼部健康参数。然后取下晶状体,并重新评估眼睛的健康状况。
结果-logMAR视力,角膜曲率或眼内压没有发现明显的变化模式。晶状体确实在结膜和角膜表面产生了变化,但是这在临床上不被认为是重要的。
结论—搜索线圈似乎并未对视觉功能产生任何重大影响。但是,应对所有线圈佩戴者进行全面的对象预筛查和磨损后检查,以确保不会造成不利影响。