AIMS—To calculate the diameter of halos perceived by patients with multifocal intraocular lenses (IOLs) and to stimulate halos in patients with refractive multifocal IOLs in a clinical experiment.
METHODS—Calculations were done to show the diameter of halos in the case of the bifocal intraocular lens. 24 patients with a refractive multifocal IOLs and five patients with a monofocal IOL were asked about their subjective observation of halos and were included in a clinical experiment using a computer program (Glare & Halo, FW Fitzke and C Lohmann, Tomey AG) which simulates a light source of 0.15 square degrees (sq deg) in order to stimulate and measure halos. Halo testing took place monoculary, under mesopic conditions through the distance and the near focus of the multifocal lens and through the focus of the monofocal lens.
RESULTS—The halo diameter depends on the pupil diameter, the refractive power of the cornea, and distance focus of the multifocal IOL as well as the additional lens power for the near focus. 23 out of 24 patients with a refractive multifocal IOL described halos at night when looking at a bright light source. Only one patient was disturbed by the appearance of halos. Under test conditions, halos were detected in all patients with a refractive multifocal IOL. The halo area testing through the distance focus was 1.05 sq deg ± 0.41, through the near focus 1.07 sq deg ± 0.49 and in the monofocal lens 0.26 sq deg ± 0.13.
CONCLUSIONS—Under high contrast conditions halos can be stimulated in all patients with multifocal intraocular lenses. The halo size using the distance or the near focus is identical.

机译:目的:在临床实验中计算多焦点人工晶状体(IOL)患者感知的光晕直径,并刺激屈光性多焦点人工晶体(IOL)患者刺激光晕。双眼人工晶状体病例。向24名屈光性多焦点IOL患者和5名单焦点IOL患者询问主观光晕,并使用计算机程序(Glare&Halo,FW Fitzke和C Lohmann,Tomey AG)进行临床实验,模拟0.15平方度(sq度)的光源,以刺激和测量光晕。光晕测试是在中视条件下通过多焦点眼镜的距离和近焦点以及单焦点眼镜的焦点进行单眼测试。
结果—光晕直径取决于瞳孔直径,角膜屈光力,多焦点IOL的远距焦点以及用于近焦点的附加镜头光焦度。 24名患有屈光性多焦点IOL的患者中有23名患者在晚上看明亮的光源时出现晕圈。只有一名患者对光环的出现感到不安。在测试条件下,所有屈光性多焦点IOL患者均检测到晕圈。通过远距焦点进行的光晕面积测试为1.05 ss deg±0.41,通过近焦点进行的光晕测试为1.07 sq deg±0.49,在单焦点镜片中的光晕面积测试为0.26 sq deg±0.13。
结论—在高光下对比情况在所有多焦点人工晶状体患者中均可激发光晕。使用距离或近焦点的光晕大小相同。