首页> 美国卫生研究院文献>The British Journal of Ophthalmology >Measuring colour rivalry suppression in amblyopia
【2h】

Measuring colour rivalry suppression in amblyopia

机译:测量弱视中的色彩竞争抑制

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

AIMS—To determine if the colour rivalry suppression is an index of the visual impairment in amblyopia and if the stereopsis and fusion evaluator (SAFE) instrument is a reliable indicator of the difference in visual input from the two eyes.
METHODS—To test the accuracy of the SAFE instrument for measuring the visual input from the two eyes, colour rivalry suppression was measured in six normal subjects. A test neutral density filter (NDF) was placed before one eye to induce a temporary relative afferent defect and the subject selected the NDF before the fellow eye to neutralise the test NDF. In a non-paediatric private practice, 24 consecutive patients diagnosed with unilateral amblyopia were tested with the SAFE. Of the 24 amblyopes, 14 qualified for the study because they were able to fuse images and had no comorbid disease. The relation between depth of colour rivalry suppression, stereoacuity, and interocular difference in logMAR acuity was analysed.
RESULTS—In normal subjects, the SAFE instrument reversed temporary defects of 0.3 to 1.8 log units to within 0.6 log units. In amblyopes, the NDF to reverse colour rivalry suppression was positively related to interocular difference in logMAR acuity (β=1.21, p<0.0001), and negatively related to stereoacuity (β=−0.16, p=0.019). The interocular difference in logMAR acuity was negatively related to stereoacuity (β=−0.13, p=0.009).
CONCLUSIONS—Colour rivalry suppression as measured with the SAFE was found to agree closely with the degree of visual acuity impairment in non-paediatric patients with amblyopia.

机译:目的:确定色彩竞争抑制是否是弱视视力的指标,以及立体视和融合评估器(SAFE)仪器是否能可靠地指示两只眼睛的视觉输入差异。
方法—为了测试SAFE仪器测量两只眼睛的视觉输入的准确性,在六个正常受试者中测量了色彩竞争抑制。将测试中性密度滤光片(NDF)放在一只眼睛前,以引起暂时的相对传入缺陷,受试者在另一只眼睛之前选择NDF以中和测试NDF。在非儿科私人诊所中,对24例诊断为单侧弱视的连续患者进行了SAFE测试。在这24只双眼动物中,有14只符合条件,因为它们能够融合图像并且没有合并症。分析了颜色竞争抑制的深度,立体视力和logMAR视力的眼内差异之间的关系。
结果-在正常受试者中,SAFE仪器将0.3到1.8 log单位的暂时缺陷反转到0.6 log单位以内。在弱视患者中,逆向色竞争抑制的NDF与logMAR视力的眼间差异呈正相关(β= 1.21,p <0.0001),与立体视力呈负相关(β= -0.16,p = 0.019)。 logMAR敏度的眼间差异与立体敏度呈负相关(β= -0.13,p = 0.009)。
结论—用SAFE测得的颜色竞争抑制与非视力障碍患者的视敏度严重相关。儿弱视患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号