首页> 美国卫生研究院文献>The British Journal of Ophthalmology >Epithelial permeability reflects subclinical effects of contact lens wear
【2h】

Epithelial permeability reflects subclinical effects of contact lens wear

机译:上皮渗透性反映了隐形眼镜佩戴的亚临床效应

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

AIMS—Recently, it was reported by the authors that a single drop fluorophotometric technique for estimating corneal epithelial permeability (Pdc) to fluorescein is not sufficiently precise for monitoring permeability changes in individual patients, but may be useful for evaluating mean differences in Pdc in population based research. To determine whether this technique provides a more sensitive index of epithelial integrity compared with conventional clinical assessments, the effects of mild corneal trauma on Pdc, the slit lamp appearance of the cornea, and corneal thickness (CT) were assessed.
METHODS—After baseline slit lamp examinations (SLE) and CT measurements, one randomly chosen eye of each of 32 normal subjects underwent 1 hour of closed eye soft contact lens (CL) wear while the fellow eye served as a control (no CL). After removing the CL, the SLE and CT measurements were repeated. Then, Pdc to fluorescein was assessed using a single drop fluorophotometric method refined to enhance feasibility, precision, and accuracy.
RESULTS—The mean (95% confidence interval) difference in natural log (Pdc) between 32 pairs of eyes (CL minus no CL) was 0.341 (0.069, 0.613), p = 0.016. By contrast, none of the 32 subjects exhibited corneal epithelial disruption upon SLE with white light following the closed eye period. Also, no substantial differences were apparent in the corneal swelling response between paired eyes, mean ΔCT (95% CI) = −2.31(−7.53, 2.91) µm, p=0.37.
CONCLUSIONS—Pdc measurements, used in studies of modest sample size, appear capable of detecting average differences in corneal barrier function that remain undetectable by SLE or pachymetry.

Keywords: contact lens; corneal epithelium; epithelial permeability; fluorophotometry; pachymetry
机译:AIMS-最近,有作者报道,单滴荧光光度法估算荧光素对角膜上皮的通透性(Pdc)不足以精确监测个别患者的通透性变化,但可能有助于评估人群中Pdc的平均差异基础研究。为了确定该技术是否提供了比常规临床评估更敏感的上皮完整性指标,评估了轻度角膜创伤对Pdc,角膜裂隙灯外观和角膜厚度(CT)的影响。
方法—在基线裂隙灯检查(SLE)和CT测量之后,对32名正常受试者中的每只随机选择的一只眼睛进行1小时闭眼软性隐形眼镜(CL)佩戴,而另一只眼睛作为对照(无CL)。去除CL后,重复SLE和CT测量。然后,通过改进以提高可行性,准确性和准确性的单滴荧光光度法评估荧光素的Pdc。
结果-32对眼睛之间的自然对数(Pdc)的平均差异(95%置信区间)( CL减去无CL)为0.341(0.069, 0.613),p = 0.016。相比之下,闭眼后在白光下SLE时32个受试者均未显示角膜上皮破坏。另外,成对的双眼之间的角膜肿胀反应也没有明显差异,平均ΔCT(95%CI)= −2.31(−7.53,2.91)μm,p = 0.37。
结论—研究中使用的Pdc测量

关键词:隐形眼镜;适度的样本量,似乎能够检测SLE或测厚法仍无法检测到的角膜屏障功能的平均差异。角膜上皮;上皮通透性荧光光度法测厚法

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号