AIMS/BACKGROUND: Comparison of the diffusion coefficient through the blood-aqueous barrier of healthy volunteers measured in different cities with identical fluorophotometers using a standardised protocol. METHODS: Healthy volunteers aged between 20 and 70 years were studied in seven European cities. The fluorescein concentration in the anterior segment of each eye was measured with a commercial scanning fluorophotometer 30 and 40 minutes after intravenous fluorescein. The decay of non-protein bound fluorescein concentration in blood plasma was determined with the use of three blood samples taken at 7, 15, and 55 minutes after injection. The diffusion coefficient through the blood-aqueous barrier was calculated from the ratio between the fluorescein concentration in the anterior chamber and the time integral of non-protein bound fluorescein concentration in plasma using specially developed software. RESULTS: The mean values of the diffusion coefficient (SD) (X10(-4) min-1) were 4.76 (1.51) (n = 20, Brussels), 5.48 (2.33) (n = 17, Coimbra), 3.47 (2.09) (n = 12, Cologne), 6.09 (2.77) (n = 21, Frankfurt), 3.85 (1.59) (n = 11, Ghent), 4.99 (1.69) (n = 23, Leiden), and 4.87 (1.05) (n = 20, Madrid). The values between centres were similar (Kruskal-Wallis test p > 0.05) except for Cologne and Frankfurt (p = 0.013). No differences were found when repeating measurements (four centres, interval time 1-8 months, Wilcoxon paired test p > 0.39). CONCLUSION: The diffusion coefficients had similar values and standard deviations. The concerted action demonstrated the usefulness of a standardised protocol.
机译:目的/背景:使用标准方案,使用相同的荧光分光光度计,在不同城市中测量的健康志愿者通过健康志愿者血水屏障的扩散系数的比较。方法:在欧洲七个城市对年龄在20至70岁之间的健康志愿者进行了研究。静脉注射荧光素后30分钟和40分钟,用市售的扫描荧光光度计测量每只眼前节中的荧光素浓度。血浆中非蛋白质结合的荧光素浓度的衰减是通过在注射后第7、15、55分钟采集的三个血样来确定的。使用专门开发的软件,由前房中的荧光素浓度与血浆中非蛋白结合的荧光素浓度的时间积分之间的比率,计算出通过血水屏障的扩散系数。结果:扩散系数(SD)(X10(-4)min-1)的平均值为4.76(1.51)(n = 20,布鲁塞尔),5.48(2.33)(n = 17,Coimbra),3.47(2.09) )(n = 12,科隆),6.09(2.77)(n = 21,法兰克福),3.85(1.59)(n = 11,根特),4.99(1.69)(n = 23,莱顿)和4.87(1.05) (n = 20,马德里)。除科​​隆和法兰克福(p = 0.013)外,中心之间的值相似(Kruskal-Wallis检验p> 0.05)。重复测量时未发现差异(四个中心,间隔时间1-8个月,Wilcoxon配对测试p> 0.39)。结论:扩散系数具有相似的值和标准偏差。共同行动证明了标准化协议的有用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号