Intraocular pressure rise after argon laser trabeculoplasty.

机译:氩激光小梁成形术后眼压升高。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Eighty-four eyes received 107 argon laser trabeculoplasty treatments at Beth Israel Medical Center between 1982 and 1984 for advanced primary and secondary glaucoma. The prelaser mean pressure was 20.25 mmHg. Pressures taken 1 1/2 hours postoperatively varied widely: the pressure rose after 47 treatments and fell or remained the same after 60. Significant increases in pressure occurred in 10 eyes, after 12 treatments; 42% of these had received burns of 0.8 watts or greater. Pressure changes were correlated with laser burn energy level. Both patients who had significant increases in pressure initially were retreated again--in the same eye--at another time had similar increases in postoperative pressure again, even with lower energy levels. Comparison with the results of previous reports highlights the advantages of limited treatment to the anterior trabeculum with low energy levels.
机译:1982年至1984年之间,八十四只眼睛在贝丝以色列医学中心接受了107例氩激光小梁成形术治疗,用于晚期原发性和继发性青光眼。激光前的平均压力为20.25mmHg。术后1 1/2小时所承受的压力变化很大:47次治疗后压力升高,而60次后压力下降或保持不变。经过12次治疗后,10只眼的压力显着增加。其中有42%的燃烧量为0.8瓦或更高。压力变化与激光燃烧能级相关。最初均显着升高压力的两名患者再次收复了治疗-在同一只眼中-在另一时间再次降低了术后压力,即使能量水平较低。与先前报告的结果进行比较,突出显示了对低能量的小梁前束进行有限治疗的优势。