摘要

BackgroundHem-o-lok clips are widely used during robot-assisted and laparoscopic radical prostatectomy to control the lateral pedicles. There are a few reports of hem-o-lok clip migration into the bladder or vesico-urethral anastomosis and only four cases of hem-o-lok clip migration resulting into bladder neck contracture. Herein, we describe the first case, to our knowledge, of hem-o-lok clip migration leading to severe bladder neck contracture and subsequent stress urinary incontinence.
机译:背景Hem-o-lok夹广泛用于机器人辅助和腹腔镜前列腺癌根治术中以控制侧蒂。仅有少数报告称“ o-o-lok”夹移入膀胱或膀胱尿道吻合,只有四例“ he-o-lok”夹移入导致膀胱颈挛缩。在本文中,就我们所知,我们描述了第一种情况,即下o-lok夹迁移导致严重的膀胱颈挛缩和随后的压力性尿失禁。