摘要

BackgroundConventional internal fixation entails the use of an interfragmentary lag screw along with a plate. Not all acetabular fractures are amenable to the placement of an interfragmentary lag screw, and the fracture may be displaced during tightening of the interfragmentary lag screw. Locking plates are a possible solution. We sought to determine whether a locking plate construct can provide stability equivalent to that provided with a conventional construct for transverse acetabular fractures.
机译:背景技术常规的内部固定需要使用片段间拉钉和板一起使用。并非所有的髋臼骨折都适合放置节间拉力螺钉,并且在拧紧节间拉力螺钉时骨折可能会移位。锁定板是一种可能的解决方案。我们试图确定锁定板结构能否提供与常规髋臼横突骨折相同的稳定性。