Comparison of tolerance to induced astigmatism in pseudophakic eyes implanted with small aperture trifocal or monofocal intraocular lenses

机译:植入小光圈三焦点或单焦点人工晶状体的假晶状体眼对诱发散光的耐受性比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: To compare the effect of induced astigmatic defocus on visual performance in pseudophakic eyes implanted with a small aperture, trifocal, or monofocal intraocular lens (IOL).>Patients and methods: The study included 44 eyes with one of four types of IOL (IC-8 IOL (AcuFocus Inc., USA); FineVision (PhysIOL SA, Belgium); AT Lisa (Carl Zeiss AG, Germany); and enVista monofocal (Bausch & Lomb, USA). For astigmatic tolerance assessment, monocular distance visual acuity was measured with cylindrical lenses (power range=0.00–2.50 diopters (D) in 0.50 D increments) added to the subjects best-corrected distance manifest refraction. The assessment was repeated on three pre-determined axes (90°, 180°, and either 45° or 135°). The magnitude of astigmatic tolerance at each defocus step was assessed by taking the difference between logMAR visual acuity at the defocus step relative to that at 0.0 D (ie, no defocus condition).>Results: Across all three axes, the reduction of mean monocular visual acuity at all defocus levels relative to no defocus was significantly smaller in IC-8 group compared to the other IOL groups. When the data was combined across all axes, the astigmatic tolerance of the IC-8 group was better than AT Lisa group from 0.50 D to 2.50 D and FineVision group from 0.50 D to 1.50 D (all P<0.05, ANOVA). The IC-8 group was better than the enVista group, but not significantly (P>0.05, ANOVA). Among individual orientations, statistically significant differences were seen between IC-8 IOLs and the other IOLs, with the largest difference being in the oblique axis. Astigmatic tolerance at all axes combined was 1.40 D for IC-8 IOL, 0.70 D for AT Lisa and FineVision, and 1.00 D for enVista IOLs.>Conclusion: The small aperture IC-8 IOL showed greater tolerance to induced astigmatic defocus compared to trifocal and monofocal IOLs.
机译:>目的:比较散光散焦对植入小光阑,三焦点或单焦点人工晶状体(IOL)的假晶状体眼的视觉性能的影响。>患者和方法:该研究包括44种眼睛,其中包括四种类型的IOL(IC-8 IOL(美国AcuFocus Inc。); FineVision(比利时PhysIOL SA); AT Lisa(德国卡尔·蔡司AG);以及enVista monofocal(Bausch&Lomb)为了评估散光容忍度,我们使用柱面透镜(屈光度范围= 0.00–2.50屈光度(D),以0.50 D的增量)测量单眼距离视敏度,将其加到受试者最佳校正的距离表现屈光度上。三个预定轴(90°,180°,以及45°或135°),每个散焦步骤的散光容忍度是通过计算散焦步骤的logMAR视敏度与0.0 D时的logMAR视敏度之差来评估的(即没有散焦条件)。>结果:在三个轴上,与其他IOL组相比,IC-8组在所有散焦水平下相对于无散焦平均单眼视力的降低明显较小。当在所有轴上组合数据时,IC-8组的散光容差在0.50 D至2.50 D时优于AT Lisa组,而在0.50 D至1.50 D时优于FineVision组(所有P <0.05,ANOVA)。 IC-8组优于enVista组,但无显着性差异(P> 0.05,ANOVA)。在各个方向之间,在IC-8 IOL和其他IOL之间观察到统计学上的显着差异,最大的差异是在斜轴上。对于IC-8 IOL,所有轴组合的像散公差为1.40 D,对于AT Lisa和FineVision为0.70 D,对于enVista IOL为1.00D。>结论:小孔径的IC-8 IOL表现出更大的公差与三焦点和单焦点IOL相比,可引起散光散焦。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号