We examined the possible reasons for common carotid artery chimney stent graft occlusion through computational fluid dynamics analyses of follow-up imaging of a patient-specific aortic configuration reconstructed from computed tomography aortography. Anatomic and hemodynamic parameters were extracted for the bilateral common carotid and subclavian arteries before and after endograft placement. Results suggested that postoperative reduction in lumen diameter within the chimney stent graft combined with an increased flow rate led to complex hemodynamics with high wall shear stress, probably resulting in high-shear thrombogenesis and chimney stent graft occlusion 2.6 years after the primary repair. Early postoperative duplex ultrasound imaging might help identify at-risk conditions.
机译:我们通过对从计算机断层扫描主动脉造影术重建的患者特定主动脉构型的后续成像进行计算流体动力学分析,研究了颈总动脉烟囱支架移植物闭塞的可能原因。植入内植前后,提取双侧颈总动脉和锁骨下动脉的解剖和血液动力学参数。结果表明,术后烟囱支架移植物内腔直径的减小以及流速的增加会导致复杂的血液动力学和高壁切应力,可能导致在初次修复后2.6年发生高剪切血栓形成和烟囱支架移植物阻塞。术后早期的双工超声检查可能有助于确定高危情况。