首页> 美国卫生研究院文献>World Journal of Gastroenterology >Assessment of hepatic VX2 tumors of rabbits with second harmonic imaging under high and low acoustic pressures
【2h】

Assessment of hepatic VX2 tumors of rabbits with second harmonic imaging under high and low acoustic pressures

机译:高和低声压下二次谐波成像对兔肝VX2肿瘤的评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

AIM: To investigate the possible clinical application value of second harmonic imaging under low acoustic pressure.METHODS: Six New Zealand rabbits, averaging 2.7 ± 0.4 kg, were selected and operated upon to construct hepatic VX2 tumor carrier model. Hepatic VX2 tumors were imaged with B mode Ultrasonography (US), and second harmonic imaging (SHI) under high mechanic index (1.6) and low mechanic index (0.1). Echo agent was intravenously injected through ear vein at a dose of 0.01 mL/kg under B mode US and high MI SHI, and 0.05 mL/kg under low MI SHI, and then the venous channel was cleaned with sterilized saline. All the images were recorded by magnetic optics (MO), and they were analyzed further by at least two independent experienced sonographers.RESULTS: Totally 6 hypoechoic and 3 hyperechoic lesions were found in the six carrier rabbits with a mean size about 2.1 ± 0.4 under B mode ultrasound, they were oval or round in shape with a clear outline or a hypoechoic halo at the margin of the lesions. Contrast agent could not change the echogenicity of the lesions under B mode US and SHI under high acoustic pressure. However, it could greatly increase the real time visualization sensitivity of the lesions with SHI under low acoustic pressure.CONCLUSION: Our results suggest that contrast enhanced SHI with low MI and a bubble non-destructive method would be much more helpful than conventional SHI in our future clinical applications.
机译:目的:探讨低声压下二次谐波成像的临床应用价值。方法:选择六只新西兰大白兔,平均体重2.7±0.4kg,进行肝VX2肿瘤携带者模型的构建。肝VX2肿瘤在B型超声(US)和二次谐波成像(SHI)的高机械指数(1.6)和低机械指数(0.1)下成像。在B模式US和高MI SHI下以0.01 mL / kg的剂量通过耳静脉静脉内注射回波剂,而在低MI SHI下以0.05 mL / kg的剂量通过耳静脉静脉内注射,然后用无菌盐水清洗静脉通道。所有图像均通过电磁光学(MO)记录,并由至少两名独立的经验丰富的超声医师进行进一步分析。结果:在六只携带兔中,总共发现了6个低回声和3个高回声病变,平均大小在2.1±0.4 B模式超声检查,它们呈椭圆形或圆形,轮廓清晰,边缘处有低回声晕。在高声压下,B模式US和SHI,造影剂不能改变病变的回声性。但是,它可以大大提高低声压下SHI病变的实时可视化敏感性。结论:我们的结果表明,对比增强的SHI具有较低的MI和较低的气泡非破坏性方法将比常规SHI在我们的研究中更有帮助未来的临床应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号