首页> 美国卫生研究院文献>Journal of Visualized Experiments : JoVE >Substantiating Appropriate Motion Capture Techniques for the Assessment of Nordic Walking Gait and Posture in Older Adults
【2h】

Substantiating Appropriate Motion Capture Techniques for the Assessment of Nordic Walking Gait and Posture in Older Adults

机译:充实适当的运动捕捉技术以评估老年人的北欧步态和姿势

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Nordic walking (NW) has become a safe and simple form of exercise in recent years, and in studying this gait pattern, various data collection techniques have been employed, each with positives and negatives. The aim was to determine the effect of NW on older adult gait and posture and to determine optimal use of different data collection systems in both short and long duration analysis. Gait and posture during NW and normal walking were assessed in 17 healthy older adults (age: 69 ± 7.3). Participants performed two trials of 6 Minute Walk Tests (6MWT) (1 with poles (WP) and 1 without poles (NP)) and 6 trials of a 5m walk (3 WP and 3 NP). Motion was recorded using two systems, a 6-sensor accelerometry system and an 8-camera 3-dimensional motion capture system, in order to quantify spatial-temporal, kinematic, and kinetic parameters.With both systems, participants demonstrated increased stride length and double support and decreased gait speed and cadence WP compared to NP (p <0.05). Also, with motion capture, larger single support time was found WP (p <0.05). With 3-D capture, smaller hip power generation and moments of force were found at heel contact and pre-swing as well as smaller knee power absorption at heel contact, pre-swing, and terminal swing WP compared to NP, when assessed over one cycle (p <0.05). Also, WP yielded smaller moments of force at heel contact and terminal swing along with larger moments at mid-stance of a gait cycle (p <0.05). No changes were found for posture.NW seems appropriate for promoting a normal gait pattern in older adults. Three-dimensional motion capture should primarily be used during short duration gait analysis (i.e. single gait cycle), while accelerometry systems should be primarily employed in instances requiring longer duration analysis such as during the 6MWT.
机译:近年来,北欧式步行(NW)已成为一种安全,简单的锻炼方式,在研究这种步态模式时,已采用了各种数据收集技术,每种技术都有其积极性和消极性。目的是确定NW对老年人步态和姿势的影响,并确定短期和长期分析中不同数据收集系统的最佳使用。在17名健康的老年人中评估了NW和正常行走过程中的步态和姿势(年龄:69±7.3)。参与者进行了6次分钟步行测试(6MWT)的两项试验(1次带杆(WP)和1次无杆(NP))和6次5m步行试验(3个WP和3个NP)。为了量化时空,运动学和动力学参数,使用了6个传感器的加速度计系统和8个摄像头的3维运动捕捉系统这两个系统来记录运动,参与者证明了这两个系统的步幅都增加了,步幅增加了一倍与NP相比,支持和步态速度及步伐WP降低(p <0.05)。同样,通过运动捕捉,发现WP的单次支持时间更长(p <0.05)。通过3D捕捉,与NP相比,与NP相比,在跟部接触和前挥时发现较小的髋部力量和力矩,在跟部接触,前挥动和最终挥杆WP中发现的膝部功率吸收较小。周期(p <0.05)。同样,WP在脚跟接触和末端摆动时产生的力矩较小,而在步态周期中途产生的力矩较大(p <0.05)。未发现姿势变化。NW似乎适合促进老年人的正常步态模式。三维运动捕捉应主要用于短时步态分析(即单步态周期),而加速度计系统应主要用于需要较长时间分析的情况下,例如6MWT。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号