Feasibility of Distributed Fiber Optic Sensor for Corrosion Monitoring of Steel Bars in Reinforced Concrete

机译:分布式光纤传感器用于钢筋混凝土中钢筋腐蚀监测的可行性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study investigates the feasibility of distributed fiber optic sensor for corrosion monitoring of steel bars embedded in concrete. Two sensor installation methods are compared: (1) attaching the sensor along the bar and (2) winding the sensor on the bar. For the second method, optical fibers were winded spirally on steel bars with different spacings: 0 mm, 2 mm, 5 mm, and 10 mm. Steel bar pull-out testing was conducted to evaluate the effect of presence of distributed sensor on the bond strength of steel–concrete interface. Electrochemical testing was carried out to assess the influence of the installation methods on the corrosion resistance of the reinforced concrete. Winding the optical fiber on steel bars with a 10-mm spacing does not affect the bond strength and corrosion resistance and allows real-time corrosion monitoring. The distributed sensor data can be used to estimate the corrosion induced steel loss and predict concrete cracking.
机译:这项研究探讨了分布式光纤传感器对埋入混凝土中的钢筋进行腐蚀监测的可行性。比较了两种传感器的安装方法:(1)将传感器沿钢筋固定,以及(2)将传感器缠绕在钢筋上。对于第二种方法,将光纤螺旋缠绕在具有不同间距的钢筋上:0毫米,2毫米,5毫米和10毫米。进行了钢筋拉拔测试,以评估分布式传感器的存在对钢筋混凝土界面粘结强度的影响。进行了电化学测试,以评估安装方法对钢筋混凝土耐腐蚀性的影响。将光纤以10 mm的间距缠绕在钢筋上不会影响粘合强度和耐腐蚀性,并允许实时腐蚀监控。分布的传感器数据可用于估计腐蚀引起的钢损并预测混凝土开裂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号