This study developed a device measuring the X-ray source-detector angle (SDA) and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR) was evaluated using the signal-to-noise (SNR), contrast-to-noise ratio (CNR), spatial resolution, distortion and entrance surface dose (ESD). According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm) and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05), whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.
机译:这项研究开发了一种测量X射线源探测器角度(SDA)的设备,并评估了用于诊断胸部图像的成像性能。 SDA设备由Arduino,加速度计和陀螺仪传感器以及蓝牙模块组成。将SDA值与数字角度计的值进行比较。使用信噪比(SNR),对比噪声比(CNR),空间分辨率,失真和入射表面剂量(ESD)评估了便携式数字射线照相(PDR)的性能。根据不同的角度度,使用五点量表评估了五个解剖学界标。平均SNR和CNR为182.47和141.43。空间分辨率和ESD为3.17 lp / mm(157μm)和0.266 mGy。与数字角度计相比,SDA设备的角度值没有显着差异。在胸部成像中,根据不同的角度度数,SNR和CNR值没有显着差异。心脏边界,第五肋骨和肩cap骨的可见度得分根据不同的角度显示出显着差异(p <0.05),而锁骨和第一肋骨的得分不显着。值得注意的是,SDA程度的增加与失真度和可见性评分的增加一致。建议的带有SDA设备的PDR根据标准放射线照相指南,可用于临床放射线照相设置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号