首页> 美国卫生研究院文献>The Open Dentistry Journal >Evaluation of Antimicrobial-Antibiofilm Activity of a Hydrogen Peroxide Decontaminating System Used in Dental Unit Water Lines
【2h】

Evaluation of Antimicrobial-Antibiofilm Activity of a Hydrogen Peroxide Decontaminating System Used in Dental Unit Water Lines

机译:牙科单位给水管线中使用的过氧化氢净化系统的抗菌-抗生物膜活性评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A dental unit water line (DUWL) equipped with a device designed to automatically and continually flush a bacteriostatic solution of hydrogen peroxide (WHE) and a discontinuous disinfecting system (BIOSTER) was evaluated. In the first instance a preliminary sensitivity test on a large number of microorganisms (bacteria and fungi) was tried with a H2O2 range from 100 to 800 ppm. The bacteria frequently reported in DUWL (including Pseudomonas spp, Streptococcus spp., Staphylococcus spp., E. coli) and some periodontal pathogens showed a minimum inhibitory concentration from 100 to 300 H2O2 ppm (also including M. marinum and C. albicans). However, H2O2 did not show any inhibitory effects against: A. actinomycetemcomitans, C. glabrata C. parapsilos, F. nucleatum, M. micros. In a second step, the DUWL was experimentally infected with S. faecalis, E. coli, P. aeruginosa, S. aureus. After disinfection steps with 3% H2O2, the inhibitory effect on planktonic forms and on sessile biofilm was measured. In a third step, the count of 16S rRNA gene copies by real time PCR at different points of the DUWL described an accrue of bacterial slime in “hot spot” regions characterized by irregular/slow water flux (valves, elbows). However these results suggest that hydrogen peroxide is not only able to inhibit bursts of planktonic bacteria inside the DUWL, but that it could also be effective against sessile biofilm containing heterotrophic microorganisms derived from domestic water line contamination. In addition some oral pathogens could be contaminating and surviving in DUWL.
机译:对配备有可自动连续冲洗过氧化氢抑菌溶液(WHE)的设备和不连续消毒系统(BIOSTER)的设备的牙科设备供水管线(DUWL)进行了评估。首先,尝试对H2O2浓度范围为100至800 ppm的大量微生物(细菌和真菌)进行初步敏感性测试。在DUWL中经常报道的细菌(包括假单胞菌属,链球菌属,葡萄球菌属,大肠杆菌)和一些牙周病原体的最低抑菌浓度为100至300 H2O2 ppm(还包括海藻分枝杆菌和白色念珠菌)。但是,H2O2对以下菌没有显示任何抑制作用:A.放线菌,C。glabrata C. parapsilos,F。nucleatum,M。micros。第二步,用粪链球菌,大肠杆菌,铜绿假单胞菌,金黄色葡萄球菌实验性感染DUWL。在用3%H2O2消毒之后,测定了对浮游形式和对无生物膜的抑制作用。第三步,通过实时PCR在DUWL的不同点对16S rRNA基因拷贝的计数描述了在“热点”区域中细菌黏液的积累,其特征是水流不规则/缓慢(阀门,弯头)。但是,这些结果表明,过氧化氢不仅能够抑制DUWL内浮游细菌的爆发,而且还可以有效地对抗含有顽固的生物膜,该生物膜含有源自生活用水线污染的异养微生物。此外,一些口腔病原体可能在DUWL中污染并存活。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号