首页> 美国卫生研究院文献>Obstetrics and Gynecology International >Antenatal Ultrasonographic Anteroposterior Renal Pelvis Diameter Measurement: Is It a Reliable Way of Defining Fetal Hydronephrosis?
【2h】

Antenatal Ultrasonographic Anteroposterior Renal Pelvis Diameter Measurement: Is It a Reliable Way of Defining Fetal Hydronephrosis?

机译:产前超声检查肾盂前后肾盂直径:这是确定胎儿肾积水的可靠方法吗?

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose. It was to quantify the intraobserver and interobserver variability of the sonographic measurements of renal pelvis and classify hydronephrosis severity. Methods. Two ultrasonographers evaluated 17 fetuses from 23 to 39 weeks of gestation. Renal pelvis APD were taken in 50 renal units. For intraobserver error, one of them performed three sequential measurements. The mean and standard deviation from the absolute and percentage differences between measurements were calculated. Bland-Altman plots were used to visually assess the relationship between the precision of repeated measurements. Hydronephrosis was classified as mild (5.0 to 9.9 mm), moderate (10.0 to 14.9 mm), or severe (≥15.0 mm). Interrater agreement were obtained using the Kappa index. Results. Absolute intraobserver variation in APD measurements was 5.2 ± 3.5%. Interobserver variation of ultrasonographers was 9.3 ± 9.7%. Neither intraobserver or interobserver error increased with increasing APD size. The overall percentage of agreement with the antenatal hydronephrosis diagnosis was 64%. Cohen's Kappa to hydronephrosis severity was 0.51 (95% CI, 0.33 to 0.69). Conclusion. Inter and intraobserver APD measurement errors were low in these group, but the agreement to hydronephrosis diagnosis and classification was fair. We suggest that standard and serial APD measurement can better define and evaluate fetal hydronephrosis.
机译:目的。量化肾盂超声检查的观察者内和观察者间变异性,并对肾积水严重程度进行分类。方法。两名超声检查人员对妊娠23至39周的17例胎儿进行了评估。肾盂APD以50个肾脏单位服用。对于观察者内错误,其中一个执行了三个顺序测量。计算出测量之间的绝对和百分比差异的平均值和标准偏差。使用布兰德-奥特曼(Bland-Altman)图来直观地评估重复测量的精度之间的关系。肾积水分为轻度(5.0至9.9 mm),中度(10.0至14.9 mm)或重度(≥15.0.mm)。使用Kappa指数获得了评估者之间的协议。结果。 APD测量中的观察者内绝对变化为5.2±3.5%。超声检查者的观察者间差异为9.3±9.7%。观察者内或观察者间错误均不会随着APD大小的增加而增加。与产前肾积水的诊断相符的总体百分比为64%。科恩氏Kappa对肾积水的严重程度为0.51(95%CI,0.33至0.69)。结论。在这些组中,观察者间和观察者内APD的测量误差均较低,但对肾积水的诊断和分类的共识尚可。我们建议标准和系列APD测量可以更好地定义和评估胎儿肾积水。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号