首页> 美国卫生研究院文献>Scientifica >A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal ProTaper Next and HyFlex CM): An Ex Vivo Study
【2h】

A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal ProTaper Next and HyFlex CM): An Ex Vivo Study

机译:通过使用不同的旋转文件(ProTaper UniversalProTaper Next和HyFlex CM)对不同仪器长度下的齿状裂纹进行立体显微镜评估:一项体内研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects.
机译:介绍。本研究的目的是用不同的器械长度评估旋转锉:Gates Glidden,ProTaper Universal,ProTaper Next和HyFlex CM根管预备后的牙本质裂缝。方法。将65个下颌前磨牙安装在带有模拟牙周膜的丙烯酸管中,并暴露其先端。用不同的旋转锉(分别是ProTaper Universal,ProTaper Next和HyFlex CM)对根管进行测量,直至根尖孔(AF),短AF和超出AF。根尖用1%亚甲蓝染料染色,并拍摄每颗牙齿顶表面的数字图像,并通过体视显微镜确定牙本质缺损的发展。进行多项逻辑回归检验以找出影响因素。结果。带有旋转锉的仪器终止了2mm短的AF,并且没有引起任何裂纹。与在顶孔处或超过顶孔处终止的器械相比,当旋转锉器械终止于1mm短的根尖孔时,观察到的裂纹明显更少(p <0.05)。结论。与ProTaper Next和HyFlex CM相比,ProTaper Universal旋转锉刀引起的牙齿裂纹更多。短AF仪器减少了牙本质缺损的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号