Handheld portable X-ray devices are increasingly used for intraoral radiography. This development introduces new challenges to staff and patient safety, for which new or revised risk assessments must be made and acted upon prior to use. Major issues might be: difficulties in using rectangular collimation with beam aiming devices, more complex matching of exposure settings to the X-ray receptor used (e.g. longer exposure times), movements owing to the units' weight, protection of the operator and third persons, and the use in uncontrolled environments. These problems may result in violation of the “as low as reasonably achievable’’, that is, ALARA principle by an increase in (re)exposures compared with the other available intraoral X-ray devices. Hence, the use of handheld portable X-ray devices should be considered only after careful and documented evaluation (which might be performed based on medical physics support), when there is evidence that handheld operation has benefits over traditional modalities and when no new risks to the operators and/or third parties are caused. It is expected that the use of handheld portable X-ray devices will be very exceptional, and for justified situations only. Special attention should be drawn to beam-aiming devices, rectangular collimation, the section of the X-ray receptor, focus–skin distance, and backscatter shielding, and that the unit delivers reproducible dose over the full set of environmental conditions (e.g. battery status and temperature).
机译:手持式便携式X射线设备越来越多地用于口腔放射照相。这种发展给工作人员和患者安全带来了新的挑战,在使用前必须对其进行新的或修订的风险评估并采取措施。主要问题可能是:难以将矩形准直仪与光束瞄准仪配合使用;将曝光设置与所使用的X射线接收器进行更复杂的匹配(例如,更长的曝光时间);由于设备的重量而引起的移动;对操作员和第三者的保护,以及在不受控制的环境中使用。与其他现有的口腔X射线设备相比,这些问题可能会导致(再)暴露量的增加,从而违反“尽可能低的合理目标”,即ALARA原则。因此,只有在有证据表明手持操作比传统方式有好处时,并且没有新的风险时,才应在进行仔细且有文件证明的评估(可能基于医学物理学支持进行评估)之后才考虑使用手持便携式X射线设备。造成运营商和/或第三方。可以预期,手持便携式X射线设备的使用将非常例外,并且仅在合理的情况下使用。应特别注意光束对准设备,矩形准直仪,X射线接收器的截面,聚焦皮肤距离和后向散射屏蔽,并且该装置在整个环境条件下(例如电池状态)都可提供可重现的剂量和温度)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号