首页> 美国卫生研究院文献>Endoscopic Ultrasound >VIDEO PLENARY 3: VID-THER-01: Endoscopic ultrasound-guided hepaticogastrostomy: Problems and solutions; some unsuccessful and then the right one!
【2h】

VIDEO PLENARY 3: VID-THER-01: Endoscopic ultrasound-guided hepaticogastrostomy: Problems and solutions; some unsuccessful and then the right one!

机译:视频全会3:VID-THER-01:内窥镜超声引导下的肝胃造口术:问题与解决方案;一些不成功然后正确的!

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A 36-year-old male presented with obstructive jaundice and acute pancreatitis. Both imaging and an upper gastrointestinal endoscopy revealed malignant duodenal obstruction involving first and second parts. The patient was managed conservatively for acute pancreatitis. Endoscopic retrograde cholangiopancreatography was not possible in view of duodenal pathology. Endoscopic ultrasound (EUS)-guided hepaticogastrostomy was planned. Walled-off pancreatic necrosis as well as ascites was noted on EUS. Hepatic duct access was gained; a guidewire placement with track dilation using 6 Fr cystotome (Endoflex) was performed. A Giobor stent (Taewoong Medical, 8 mm × 10 cm long) was placed between the liver and stomach; immediate migration of the stent was noted resulting in to the impaction of the proximal end in to the gastric wall. Retrieval attempts made over the in-stent placement of a 7 Fr. Double pigtail plastic stent was unsuccessful. Plastic stent was removed after stent intubation carried out over a guidewire placed through the side hole. Retrieval using a Hurricane balloon (8 mm, Boston Scientific) was also unsuccessful. Eventually, successful biliary drainage was performed using both bare (10 mm × 60 mm, Taewoong Medical) biliary metal stent placement through the Giobor stent. An enteral stent (WallFlex Duodenal, Boston Scientific) was placed for the duodenal obstruction.
机译:一名36岁的男性出现梗阻性黄疸和急性胰腺炎。影像学检查和上消化道内窥镜检查均显示恶性十二指肠阻塞,涉及第一和第二部分。保守治疗急性胰腺炎。鉴于十二指肠病理,不可能进行内镜逆行胰胆管造影。计划内镜超声(EUS)引导的肝胃造口术。在EUS上发现了胰腺坏死和腹水。肝导管进入;使用6 Fr膀胱切除器(Endoflex)进行带径扩张的导丝放置。将Giobor支架(Taewoong Medical,长8 mm×10 cm)放置在肝和胃之间;注意到支架立即迁移,导致近端冲击到胃壁。尝试在支架内放置7Fr。双尾纤塑料支架未成功。在通过侧孔放置的导丝上进行支架插管后,取出塑料支架。使用飓风气球(8毫米,Boston Scientific)进行的检索也没有成功。最终,通过Giobor支架将裸露的(10 mm×60 mm,Taewoong Medical)胆管金属支架放置成功完成了胆管引流。肠内支架(WallFlex Duodenal,Boston Scientific)被放置用于十二指肠阻塞。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号