摘要

Controlled parallel experiments were performed on the Vienna test model for the evaluation of procedures for hygienic hand-disinfection in three laboratories (Vienna, Mainz, Birmingham). The degerming activity of four procedures, each taking 1 min, was assessed repeatedly and compared with that of a standard disinfection procedure (ST) using isopropanol 60% (v/v). The mean log reductions (mean log RF) for each procedure were as follows: n-propanol 50% (v/v) 4.85 and 5.14 in Vienna (V) and Mainz (M) respectively, ethanol 70% (v/v) + chlorhexidine-gluconate 0.5% (w/v), 4.01 (V), 3.76 (M) and 4.00 in Birmingham (B). Washing procedures were less effective, mean log RF's of 3.19 (V), 3.49 (M) and 3.04 (B) were obtained with povidone-iodine soap, and 2.91 (V), 3.37 (M) and 3.27 (B) with a liquid phenolic soap. Analysis of variance on the data from Vienna and Mainz revealed significant differences of means not only between procedures ('preparations') but also on repeat testing. To compensate for the influence of variables such as test subjects, laboratory and day, the Vienna test model provides a method of standardization by testing a ST in parallel with the test procedure (P). Standardization of the results was obtained by pair-wise substraction, log RFPi-log RFSTi. Analysis of variance on the resulting values demonstrated that comparability of the results between laboratories and on repeat testing was achieved. The relative variation of the measurements within the laboratories ranged from 0.9 to 4.2%. As assessed by power-analysis, a disinfection procedure will be detected as significantly (P = 0.1) inferior to the standard processes in 95 of 100 experiments if it produces a mean log RF that is at least 0.55-0.65 log units smaller than that of the standard.
机译:在维也纳试验模型上进行了对照平行实验,以评估三个实验室(维也纳,美因茨,伯明翰)中手部卫生消毒的程序。重复评估四个过程的脱菌活性,每个过程耗时1分钟,并与使用60%异丙醇(v / v)的标准消毒过程(ST)的相比。每个程序的平均对数减少量(平均对数RF)如下:正丙醇50%(v / v)在维也纳(V)和美因茨(M)分别为4.85和5.14,乙醇70%(v / v)+伯明翰(B)中的0.5%(w / v),4.01(V),3.76(M)和4.00的氯己定-葡萄糖酸盐。洗涤程序效果较差,用聚维酮碘皂获得的平均log RF值为3.19(V),3.49(M)和3.04(B),而液体的平均log RF值为2.91(V),3.37(M)和3.27(B)酚醛肥皂。对来自维也纳和美因茨的数据的方差分析表明,不仅程序(“准备”)之间的均值存在显着差异,而且重复测试也存在差异。为了补偿变量的影响,例如测试对象,实验室和日期,Vienna测试模型通过与测试程序(P)并行测试ST提供了一种标准化方法。结果的标准化是通过成对减法(log RFPi-log RFSTi)获得的。对结果值的方差分析表明,实验室之间和重复测试的结果具有可比性。实验室中测量值的相对变化范围为0.9%至4.2%。根据功效分析评估,如果消毒程序产生的平均log RF值至少比标准方法的log log值小0.55-0.65 log个单位,则在100个实验中有95个被检测为显着(P = 0.1)次于标准过程。标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号