Evaluation of Stability of Surface-Treated Mini-Implants in Diabetic Rabbits

机译:糖尿病兔经表面处理的小扩增子的稳定性评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Introduction. The purpose of this study was to investigate effects of surface treatment of mini-implants in diabetes-induced rabbits by comparing osseointegration around mini-implants. Methods. Twelve New Zealand white rabbits were divided into two groups (alloxan-induced diabetic group and control group). A total of 48 mini-implants were placed after four weeks of diabetic induction. 24 mini-implants were surface-treated with SLA (sandblasted with large grit, and acid etched) and the remaining 24 mini-implants had smooth surfaces. Four weeks after placement, 32 mini-implants were removed from 4 control and 4 diabetic rabbits. Insertion and removal torques were measured. The remaining 16 mini-implants from the two groups were histomorphometrically analyzed. Results. Maximum insertion torque showed no difference between diabetic and control groups, but total insertion energy was higher in control group. In surface-treated mini-implants, maximum removal torque was higher in both diabetic and control groups. Bone-implant contact (BIC) was increased in the control group when compared to the diabetic group. Surface-treated group had higher BIC than smooth surface group in both control and diabetic groups. However, there was no significantly statistical difference. Conclusions. Type 1 diabetes mellitus and surface treatment method of mini-implant affected primary stability of mini-implants. In addition, the use of orthodontic mini-implants in a diabetic patient is likely to show results similar to the healthy patient.
机译:介绍。这项研究的目的是通过比较微型植入物周围的骨整合来研究微型植入物在糖尿病诱导的兔子中的表面处理效果。方法。将十二只新西兰白兔分为两组(四氧嘧啶致糖尿病组和对照组)。糖尿病诱导四周后,总共放置了48个微型植入物。用SLA对24个微型植入物进行表面处理(喷砂处理后用大粒度喷砂并酸蚀),其余24个微型植入物的表面光滑。放置后四周,从4只对照兔和4只糖尿病兔中取出32个微型植入物。测量插入和移除扭矩。对两组剩余的16种微型植入物进行了组织形态计量学分析。结果。糖尿病组和对照组之间最大插入扭矩无差异,但对照组的总插入能量更高。在经过表面处理的微型植入物中,糖尿病组和对照组的最大去除扭矩都更高。与糖尿病组相比,对照组的骨植入物接触量(BIC)增加。在对照组和糖尿病组中,表面处理组的BIC均高于光滑表面组。但是,没有明显的统计学差异。结论。 1型糖尿病和微型植入物的表面处理方法影响微型植入物的基本稳定性。此外,在糖尿病患者中使用正畸微型植入物可能会显示出与健康患者相似的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号