首页> 美国卫生研究院文献>International Journal of Dentistry >Surface Roughness Microhardness and Microleakage of a Silorane-Based Composite Resin after Immediate or Delayed Finishing/Polishing
【2h】

Surface Roughness Microhardness and Microleakage of a Silorane-Based Composite Resin after Immediate or Delayed Finishing/Polishing

机译:立即或延迟完成/抛光后基于硅氧烷的复合树脂的表面粗糙度显微硬度和显微渗漏

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective. This study evaluated the effect of immediate or delayed finishing/polishing using different systems on the surface roughness, hardness, and microleakage of a silorane-based composite. Material and Methods. Specimens were made with silorane-based composite (Filtek P90, 3M ESPE) and assigned to the treatments: control (light-cured); aluminum oxide discs (Sof-Lex, 3M ESPE); diamond-impregnated silicone tips (Astropol, Ivoclar Vivadent); aluminum oxide-impregnated silicone tips (Enhance, Dentsply). Half of the specimens were finished/polished immediately and the rest after 7 days. Surface roughness (Ra, μm; n = 20) and Vickers microhardness (50 g; 45 s; n = 10) were measured. Cavities were prepared in bovine incisors and filled with Filtek P90. The fillings received immediate or delayed finishing/polishing (n = 10) and were subjected to dye penetration test (0.5% basic fuchsin, 24 h). Data were analyzed by ANOVA and Scheffe, Kruskal-Wallis, and Mann-Whitney tests (p < 0.05). Results. The finishing/polishing system significantly influenced roughness and microhardness (p < 0.0001). For enamel, microleakage was not affected by the finishing/polishing system (p = 0.309). For dentin, Sof-Lex discs and Astropol points promoted greater microleakage than Enhance points (p = 0.033). Conclusion. Considering roughness, microhardness, and microleakage together, immediate finishing/polishing of a silorane-based composite using aluminum oxide discs may be recommended.
机译:目的。这项研究评估了使用不同系统立即或延迟完成/抛光对硅氧烷基复合材料表面粗糙度,硬度和微渗漏的影响。材料与方法。用基于硅氧烷的复合材料(Filtek P90,3M ESPE)制成样品,并分配给以下处理:对照(​​光固化);氧化铝盘(Sof-Lex,3M ESPE);金刚石浸渍的硅树脂笔尖(Astropol,Ivoclar Vivadent);氧化铝浸渍的硅树脂笔尖(增强,Dentsply)。一半样本立即完成/抛光,其余样本在7天后完成。测量表面粗糙度(Ra,μm; n = 20)和维氏显微硬度(50μg;45μs; n = 10)。在牛切牙中准备腔体并填充Filtek P90。填料立即或延迟进行抛光/抛光(n = 10),并进行染料渗透测试(0.5%碱性品红,24 h)。数据通过ANOVA和Scheffe,Kruskal-Wallis和Mann-Whitney检验进行了分析(p <0.05)。结果。抛光/抛光系统显着影响粗糙度和显微硬度(p <0.0001)。对于搪瓷,微渗漏不受抛光/抛光系统的影响(p = 0.309)。对于牙本质,Sof-Lex椎间盘和Astropol点促进的微渗漏比增强点(p = 0.033)更大。结论。综合考虑粗糙度,显微硬度和显微渗漏,建议立即使用氧化铝圆盘对硅氧烷基复合材料进行精加工/抛光。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号