Background: The effectiveness of ready-to-use disinfectant wipes was previously assessed in standardized suspension tests, which were inadequate because they ignored that the wipes are rubbed against a surface. Thus, we assessed the effectiveness of commercially available disinfectant wipes impregnated with an alcoholic solution according to the 16615 standard, which includes a test with mechanical action. Methods: According to the EN 16615 standard, under clean conditions, four squares (5 cm × 5 cm), placed next to one another, were marked on a test surface. Enterococcus hirae, Pseudomonas aeruginosa, and Staphylococcus aureus were inoculated on the leftmost square, and a wipe impregnated with an alcoholic solution was placed to the left of that square. Then, the wipe was pressed with a 2.5 kg weight and moved to the right and back to the left. After contact times of 1, 5, 10, or 15 min, we measured the reduction in bacterial load. Results: Alcohol-based ready-to-use commercial wipes did not show sufficient bactericidal activity at the contact times of 1, 5, 10 and 15 min. Wipes containing propan-1-ol and a mixture of propan-1-ol and propan-2-ol were active against Pseudomonas aeruginosa at the contact times of 1 min and 15 min. None of the examined wipes were active against Enterococcus hirae or Staphylococcus aureus. Conclusion: Bactericidal parameters of ready-to-use disinfectant wipes should be determined in surface tests, in addition to suspension tests, because suspension tests do not simulate the conditions under which disinfectant wipes are used in practice.
机译:背景:以前曾在标准化的悬架测试中评估了即用型消毒湿巾的有效性,但该效果尚不充分,因为他们忽略了湿巾在表面上的摩擦。因此,我们评估了根据16615标准用酒精溶液浸渍的市售消毒湿巾的有效性,其中包括具有机械作用的测试。方法:根据EN 16615标准,在干净的条件下,将四个正方形(5 cm×5 cm)彼此相邻放置,标记在测试表面上。在最左边的正方形上接种平肠球菌,铜绿假单胞菌和金黄色葡萄球菌,并在该正方形的左侧放置浸有酒精溶液的抹布。然后,以2.5公斤重压拭擦拭巾,然后向右移动并向左移动。在1、5、10或15分钟的接触时间后,我们测量了细菌载量的减少。结果:基于酒精的即用型擦拭巾在接触时间分别为1、5、10和15分钟时未显示出足够的杀菌活性。含有丙-1-醇以及丙-1-醇和丙-2-醇的混合物的湿巾在接触时间分别为1分钟和15分钟时对铜绿假单胞菌具有活性。所检查的擦巾均没有抗平肠球菌或金黄色葡萄球菌的活性。结论:除悬浮测试外,应在表面测试中确定即用型消毒湿巾的杀菌参数,因为悬浮测试不能模拟实际使用消毒湿巾的条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号