Microbiology safety cabinet disinfection procedures using formaldehyde have been tested. Tubercle bacilli were killed by concentrations of formaldehyde obtained by heating commercial formalin irrespective of whether the bacilli were in the cabinet free space or above the prefilters. However, Bacillus stearothermophilus spore papers for for the testing of low temperature steam/formaldehyde sterilisers were almost never sterilised and a strain of Staphylococcus epidermidis (NCTC 7944) showed a resistance intermediate between the B stearothermophilus spores and the tubercle bacilli. Tests using a vaccine strain of poliovirus type 3 indicated a considerable degree of resistance of the virus to the action of formaldehyde. No such resistance was demonstrated by vaccinia virus or echovirus 14. Chemical and biological evidence is presented which indicates that filter paper discs are an unsuitable carrier material for a challenge organism in testing the efficiency of any formaldehyde sterilising process. Recommendations are made towards developing a satisfactory test procedure.
机译:已经测试了使用甲醛的微生物安全柜消毒程序。结核杆菌是通过加热商品福尔马林而获得的甲醛浓度杀死的,而不论细菌是在橱柜自由空间内还是在预过滤器上方。然而,用于测试低温蒸汽/甲醛灭菌剂的嗜热脂肪芽孢杆菌芽孢纸几乎从未灭菌,表皮葡萄球菌菌株(NCTC 7944)显示在嗜热脂肪芽孢杆菌B孢子和结核杆菌之间有抗性中间产物。使用3型脊髓灰质炎病毒疫苗株的测试表明,该病毒对甲醛的作用具有相当程度的抗性。牛痘病毒或回声病毒14均未显示出这种耐药性。化学和生物学证据表明,滤纸圆盘对于测试任何甲醛灭菌过程的效率而言,是挑战生物体的不合适载体材料。为制定令人满意的测试程序提出了建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号