首页> 美国卫生研究院文献>Clinical and Diagnostic Laboratory Immunology >Validation of a Single-Platform Volumetric CD45-Assisted PanLeucogating Auto40 Flow Cytometer To Determine the Absolute Number and Percentages of CD4 T Cells in Resource-Constrained Settings Using Cameroonian Patients Samples
【2h】

Validation of a Single-Platform Volumetric CD45-Assisted PanLeucogating Auto40 Flow Cytometer To Determine the Absolute Number and Percentages of CD4 T Cells in Resource-Constrained Settings Using Cameroonian Patients Samples

机译:验证单平台体积较大CD45辅助的PanLeucogating Auto40流式细胞仪以使用喀麦隆患者的样本确定资源受限情况下CD4 T细胞的绝对数量和百分比

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The study evaluated the single-platform, volumetric, CD45-assisted PanLeucogating Auto40 flow cytometer (Apogee Flow Systems Ltd., Hemel Hempstead, United Kingdom) for CD4 T cell numeration, compared to the reference FACSCalibur flow cytometer. Results of absolute counts and percentages of CD4 T cells by Auto40 and FACSCalibur of 234 tripotassium EDTA (K3-EDTA)-blood samples from 146 adults and 88 children (aged from 18 months to 5 years), living in Yaoundé, Cameroon, were highly correlated (r2 = 0.97 and r2 = 0.98, respectively). The mean absolute bias and relative bias between Apogee Auto40 and FACSCalibur absolute CD4 T cell counts were +9.6 cells/μl, with limits of agreement from −251 to 270 cells/μl, and +4.1%, with limits of agreement from −16.1 to 24.4%, respectively. The mean absolute bias and relative bias between Apogee Auto40 and FACSCalibur CD4 T cell results expressed as percentages were +0.05% CD4 (95% confidence interval [CI], −0.03 to 0.41), with limits of agreement from −6.0 to 5.9% CD4, and +1.0%, with limits of agreement from −32.3 to 34.4%, respectively. The Auto40 counting allowed identification of the majority of adults with CD4 T cell counts below 200 cells/μl (sensitivity, 87%; specificity, 98%) or below 350 cells/μl (sensitivity, 92%; specificity, 98%) and of children with CD4 T cell counts below 750 cells/μl (sensitivity, 82%; specificity, 98%) or below 25% CD4+ (sensitivity, 96%; specificity, 99%). The Auto40 analyzer is a reliable alternative flow cytometer for CD4 T lymphocyte enumeration to be used in routine immunological monitoring according to the WHO recommendations for HIV-infected adults as well as children living in resource-constrained settings.
机译:与参考FACSCalibur流式细胞仪比较,该研究评估了CD45辅助的单平台,容积式PanLeucogating Auto40流式细胞仪(Apogee Flow Systems Ltd.,Hemel Hempstead,英国)。通过Auto40和FACSCalibur对来自喀麦隆雅温得的146名成年人和88名儿童(年龄从18个月至5岁)的234份EDTA(K3-EDTA)血液样本的CD4 T细胞的绝对计数和百分比的结果非常高相关(r 2 = 0.97和r 2 = 0.98)。 Apogee Auto40和FACSCalibur CD4 T绝对细胞计数之间的平均绝对偏倚和相对偏倚为+9.6细胞/μl,一致限从-251至270细胞/μl,以及+ 4.1%,一致同意限从-16.1至分别为24.4%。 Apogee Auto40和FACSCalibur CD4 T细胞结果之间的平均绝对偏倚和相对偏倚以百分比表示,为+ 0.05%CD4(95%置信区间[CI],-0.03至0.41),一致极限从-6.0至5.9%CD4 ,以及+ 1.0%,协议限制分别为-32.3至34.4%。通过Auto40计数,可以识别大多数CD4 T细胞计数低于200细胞/μl(敏感性为87%;特异性为98%)或低于350细胞/μl(敏感性为92%;特异性为98%)的成年人。 CD4 T细胞的儿童计数低于750个细胞/微升(敏感性82%;特异性98%)或CD4 + 25%以下(敏感性96%;特异性99%)。 Auto40分析仪是CD4 T淋巴细胞计数的可靠替代流式细胞仪,可根据WHO对HIV感染成年人和生活在资源有限环境中的儿童的建议,用于常规免疫学监测。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号