摘要

>Aims: To investigate alternative relations between cumulative exposures to hand-transmitted vibration (taking account of vibration magnitude, lifetime exposure duration, and frequency of vibration) and the development of white finger (Raynaud's phenomenon). >Methods: Three previous studies have been combined to provide a group of 1557 users of powered vibratory tools in seven occupational subgroups: stone grinders, stone carvers, quarry drillers, dockyard caulkers, dockyard boilermakers, dockyard painters, and forest workers. The estimated total operating duration in hours was thus obtained for each subject, for each tool, and for all tools combined. From the vibration magnitudes and exposure durations, seven alternative measurements of cumulative exposure were calculated for each subject, using expressions of the form: dose = ∑amiti, where ai is the acceleration magnitude on tool i, ti is the lifetime exposure duration for tool i, and m = 0, 1, 2, or 4. >Results: For all seven alternative dose measures, an increase in dose was associated with a significant increase in the occurrence of vibration-induced white finger, after adjustment for age and smoking. However, dose measures with high powers of acceleration (m > 1) faired less well than measures in which the weighted or unweighted acceleration, and lifetime exposure duration, were given equal weight (m = 1). Dose determined solely by the lifetime exposure duration (without consideration of the vibration magnitude) gave better predictions than measures with m greater than unity. All measures of dose calculated from the unweighted acceleration gave better predictions than the equivalent dose measures using acceleration frequency-weighted according to current standards. >Conclusions: Since the total duration of exposure does not discriminate between exposures accumulated over the day and those accumulated over years, a linear relation between vibration magnitude and exposure duration seems appropriate for predicting the occurrence of vibration-induced white finger. Poorer predictions were obtained when the currently recommended frequency weighting was employed than when accelerations at all frequencies were given equal weight. Findings suggest that improvements are possible to both the frequency weighting and the time dependency used to predict the development of vibration-induced white finger in current standards.
机译:>目的:研究手传播的振动的累积暴露量(考虑到振动幅度,寿命暴露持续时间和振动频率)与白手指发育(雷诺现象)之间的替代关系。 >方法:以前的三项研究相结合,为七个职业亚组中的1557个电动振动工具用户提供了磨碎机,石雕工,采石场钻工,船坞填缝机,船坞锅炉制造商,船坞油漆工和森林工人。这样就获得了每个主题,每个工具以及所有组合工具的估计总运行时间(小时)。根据振动幅度和暴露持续时间,使用以下形式的表达式为每个受试者计算出七个累积暴露的替代测量值:剂量= ∑a m iti,其中ai是工具i上的加速度幅度, ti是工具i的寿命暴露持续时间,m = 0、1、2或4。>结果:对于所有七个替代剂量测量,剂量的增加与剂量的显着增加有关。调整年龄和吸烟后,会发生由振动引起的白手指。但是,具有较高加速功率(m> 1)的剂量测量的公平性不如对加权或未加权的加速以及生命暴露持续时间赋予相等权重(m = 1)的测量。仅由寿命暴露持续时间确定的剂量(不考虑振动幅度)比m大于1的量度提供了更好的预测。与根据当前标准使用加速频率加权的等效剂量测量值相比,从未加权加速度计算的所有剂量测量值均能提供更好的预测。 >结论:由于总的暴露时间无法区分一天中累积的暴露量和多年中累积的暴露量,因此振动幅度与暴露时间之间的线性关系似乎适合预测振动引起的白色现象的发生手指。当使用当前推荐的频率加权时,与在所有频率下的加速度都赋予相同的权重相比,获得的预测效果较差。研究结果表明,在当前标准中,用于预测振动引起的白指发展的频率加权和时间依赖性都可能得到改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号