首页> 美国卫生研究院文献>British Heart Journal >Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method
【2h】

Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method

机译:彩色多普勒速度分布积分法对房间隔缺损患者肺与全身血流之比的无创自动化评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: The recent introduction of the automated cardiac flow measurement (ACM) method, using spatiotemporal integration of the Doppler velocity profile, provides a quick and accurate automated calculation of cardiac output.>Objective: To evaluate the ACM method against oximetry during cardiac catheterisation for estimating the Qp/Qs (pulmonary to systemic flow) ratio in patients with an atrial septal defect.>Methods: Left and right ventricular stroke volume (LVSV, RVSV) were calculated by ACM in 22 patients with an atrial septal defect who underwent cardiac catheterisation and in 11 patients without heart disease (control group). With ACM, the Qp/Qs ratio was estimated from RVSV divided by LVSV. In the patients with an atrial septal defect, the Qp/Qs ratio was assessed by oximetry at the time of cardiac catheterisation.>Results: There was a good correlation between LVSV and RVSV obtained by ACM in the control group (r = 0.98, y = 0.97x + 0.25, SEE = 2.9 ml). The mean difference between LVSV and RVSV by ACM was −1.25 (2.76) ml. The Qp/Qs ratio obtained by ACM in the control group was 0.98 (0.06). The Qp/Qs ratio in patients with an atrial septal defect was significantly higher than in the control group (3.11 (1.20), p < 0.001). ACM determination of the Qp/Qs ratio correlated well with oximetry determination (r = 0.86, y = 0.75x + 0.55, SEE = 0.64). The mean difference between ACM and oximetry for the measurement of the Qp/Qs ratio was −0.28 (0.69).>Conclusions: The newly developed ACM method is clinically useful for non-invasive automated estimations of the Qp/Qs ratio in patients with an atrial septal defect.
机译:>背景:最近引入的自动心流测量(ACM)方法使用多普勒速度分布的时空积分,可以快速准确地自动计算心输出量。>目标:评价ACM方法在心脏导管插入术期间抗血氧饱和度的方法,以评估房间隔缺损患者的Qp / Qs(肺对全身血流)比率。>方法::左右心室搏动量(LVSV) ARV计算22例接受心脏导管插入的房间隔缺损患者和11例无心脏病的患者(对照组)。对于ACM,根据RVSV除以LVSV估算Qp / Qs比。在房间隔缺损的患者中,在心脏导管插入术时通过血氧测定法评估Qp / Qs比值。>结果:对照组中ACM获得的LVSV和RVSV之间具有良好的相关性(r = 0.98,y = 0.97x + 0.25,SEE = 2.9 ml)。 ACM的LVSV和RVSV之间的平均差为-1.25(2.76)ml。对照组中ACM获得的Qp / Qs比为0.98(0.06)。房间隔缺损患者的Qp / Qs比值显着高于对照组(3.11(1.20),p <0.001)。 ACM测定Qp / Qs比率与血氧测定法密切相关(r = 0.86,y = 0.75x + 0.55,SEE = 0.64)。 ACM和血氧测定法测量Qp / Qs比的平均差为-0.28(0.69)。>结论:新开发的ACM方法可用于无创自动评估Qp / Qs。房间隔缺损患者的Qs比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号