The Inoue balloon for dilatation of the tricuspid valve: a modified over-the-wire approach.

机译:用于三尖瓣扩张的井上气球:一种改良的线控方式。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The Inoue balloon was used for dilatation of tricuspid stenosis in a 74 year old woman. The valve was reached by an over-the-wire approach with a 0.025 exchange length guide wire. The Inoue stylet would not reach the tricuspid orifice because the right atrium was so large. The Inoue balloon's special dilatation characteristics allowed good positioning at the tricuspid orifice. After dilatation to 27.5 mm, the pressure drop across the valve was reduced from 12 to 5 mm Hg. Further dilatation at 30 mm, however, created moderately severe tricuspid reflux without a further reduction of gradient. The Inoue balloon is suitable for dilatation of tricuspid stenosis but small increments in dilatation size may be required for optimal reduction in gradient without creating significant reflux.
机译:井上球囊用于扩张一名74岁妇女的三尖瓣狭窄。阀是通过线径为0.025的交换长度导丝到达的。井上探针无法到达三尖瓣口,因为右心房太大。井上气球的特殊膨胀特性使其可以很好地定位在三尖瓣口处。膨胀至27.5毫米后,整个阀门的压降从12毫米汞柱降至5毫米汞柱。然而,在30mm处进一步扩张会产生中等程度的严重三尖瓣反流,而不会进一步降低梯度。 Inoue球囊适合于三尖瓣狭窄的扩张,但可能需要扩张幅度的小幅增加,以实现梯度的最佳降低而不会产生明显的回流。