首页> 美国卫生研究院文献>British Heart Journal >Evaluation of exercise electrocardiography and thallium tomographic imaging in detecting asymptomatic coronary artery disease in diabetic patients.
【2h】

Evaluation of exercise electrocardiography and thallium tomographic imaging in detecting asymptomatic coronary artery disease in diabetic patients.

机译:评价运动心电图和th体层成像在糖尿病患者中无症状冠状动脉疾病的检测。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Thallium tomographic imaging and exercise electrocardiography were performed on 136 diabetic patients without symptoms of heart disease. Thirty three patients had post-exercise thallium defects and 19 had ST 1 mm greater than or equal to segment depression during exercise electrocardiography. Both tests were positive in 13 patients. Coronary angiography was subsequently performed on 33 patients with either scintigraphic and/or electrocardiographic evidence of myocardial ischaemia. Angiographically significant coronary artery disease (greater than or equal to 50% narrowing of the coronary artery lumen) was detected in 13 patients. Six patients had minimal coronary artery stenosis (less than 50%), and 14 had normal coronary arteries. Six patients refused cardiac catheterisation. In 14 out of 27 patients with post-exercise thallium defects coronary angiography did not show any coronary artery stenoses (positive predictive accuracy 48%). Exercise electrocardiography showed only one false positive result (positive predictive accuracy 94%) but failed to detect coronary artery disease in three patients with a positive scintigraphic result. The accuracy of a positive exercise electrocardiographic test seems to be better than that of a positive thallium tomographic scan for detecting asymptomatic coronary artery disease in diabetic patients. The high number of false positive thallium defects may be the result of technical features inherent in thallium tomography and/or the possible disease of the small intramyocardial arteries in diabetic patients.
机译:对136例无心脏病症状的糖尿病患者进行了to体层显像和运动心电图检查。在运动心电图检查中,有33例运动后th缺陷患者,其中19例ST大于或等于节段压低1 mm。两项测试均阳性13例。随后对33例有心肌缺血迹象和/或心电图证据的患者进行了冠状动脉造影。在13例患者中发现了具有血管造影意义的冠状动脉疾病(大于或等于50%的冠状动脉腔狭窄)。 6例患者的冠状动脉狭窄程度最小(少于50%),而14例具有正常的冠状动脉。六名患者拒绝心脏导管插入术。在运动后al缺陷的27例患者中,有14例冠状动脉造影未显示任何冠状动脉狭窄(阳性预测准确性为48%)。运动心电图检查仅显示一个假阳性结果(阳性预测准确率94%),但在3个闪烁显像结果阳性的患者中未能检测到冠心病。积极运动心电图检查的准确性似乎比阳性a体层断层扫描的准确性要好,以检测糖尿病患者的无症状冠状动脉疾病。大量假阳性th缺陷可能是may断层扫描固有的技术特征和/或糖尿病患者心肌小动脉可能发生的疾病的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号