首页> 美国卫生研究院文献>AORTA Journal >A Rare and Late Complication After Left Ventricular Assist Device Explantation
【2h】

A Rare and Late Complication After Left Ventricular Assist Device Explantation

机译:左心室辅助装置植入后的罕见和晚期并发症

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Late complications can arise after explantation of a left ventricular assist device. We report the case of a patient who presented at the age of 19 years with peri-partum cardiomyopathy and was initially managed with a biventricular support device, which was subsequently upgraded to an ambulatory left ventricular assist device. This was successfully explanted after myocardial recovery via a minimally invasive approach 7 months later. The patient re-presented 5 years following explantation with hemoptysis. At redo sternotomy, a 10-cm remnant of the outflow graft was found to be eroding the surface of the right lung. The conduit was excised and the stump oversewn. Eleven months later, she presented again with hemoptysis, and a pseudo-aneurysm was identified on the computed tomography scan. She underwent urgent open repair with peripheral cannulation and deep hypothermic total circulatory arrest. The Dacron stump was found to be partially dehisced, leaving a 2–3 cm defect in the ascending aorta. The defect was repaired with a bovine pericardial patch. The patient made a good recovery and was successfully discharged.
机译:植入左心室辅助装置后可能会出现晚期并发症。我们报道了一名患者,该患者在19岁时出现围产期心肌病,最初使用双心室支持设备进行治疗,随后将其升级为动态左心室辅助设备。 7个月后,通过微创方法将其成功移植出心肌。该患者在移植后5年出现咯血。重做胸骨切开术时,发现流出的移植物的10厘米残余物腐蚀了右肺表面。导管被切除,树桩被缝合。 11个月后,她再次出现咯血,并且在计算机断层扫描中发现了假性动脉瘤。她接受了紧急的开放式修复,包括外周插管和深低温完全循环停止。发现Dacron树桩部分开裂,在升主动脉中留下2-3 cm的缺损。用牛心包膜修补缺损。病人恢复良好,已成功出院。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号