首页> 中文期刊> 《世界临床泌尿杂志》 >Penile prosthesis:Patient satisfaction,use and preference for malleable vs inflatable

Penile prosthesis:Patient satisfaction,use and preference for malleable vs inflatable

         

摘要

AIM:To evaluate and compare long-term patient satisfaction and use after either malleable penile prosthesis(MPP)or inflatable penile prosthesis(IPP)implantation.METHODS:we present a retrospective unicenter study of 108 patients implanted with either 2 or 3-piece American Medical System^TM(AMS^TM)or Coloplast^TMinflatable penile prosthesis(AMS 700CX^TM,AMS 700CXR^TM,AMS Ambicor?or Coloplast TITAN^TM)or malleable(AMS Spectra^TM or Coloplast Genesis^TM)in our Centre between 1993 and 2011.We collected data from the medical record including follow-up,age and type of prosthesis.We used a four-question telephone survey designed ad hoc by urologist in our Department,with three multiple choice questions and a grading answer.After verbal consent was obtained,proposed questions concerned global satisfaction regarding to the procedure,quality of sexual intercourses graded from 0 to 10,frequency of sexual intercourse and about undergoing the same procedure again.SPSS^TM version 20.0 was used for the descriptive analysis of the data.RESULTS:Sixty seven(64%)patients underwent a MPP and 41(36%)an IPP.The mean age was 52.6±3.6 years in the MPP group and 57.2±2.8 years in the IPP group(P=0.02).Total respond rate was 55.5%(60/108).Twenty six out of 33 MPP patients(78.9%)and 19 of the 27 IPP subjects(70.3%)were satisfied or very satisfied with the procedure.The quality of sexual intercourse was rated 7.13±0.39 points in the MPP group and 6.16±0.47 points in the IPP group.Frequency of sexual intercourse was 1 or more times per week in 15(46.9%)patients with MPP and in 12(46.1%)of the IPP patients.Twenty-eight(84.9%)patients who received a MPP would undergo the procedure for the same device again as well as 24(88.9%)of the IPP group.There were no statistical differences between groups regarding the four items in the survey.CONCLUSION:Patients show high satisfaction rate and no statistical differences exist regarding to global satisfaction,use of the device and quality of sexual intercourse depending on the type of penile prosthesis.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号