Reserviors under other constructions are area-saving and extensive attention is being attracted.Aiming at these two characteristic,key points to optimize the design for clean water reservoirs overlapped under other constructions are discussed.The confirmation of water levels is different,if the reservoirs are connected in series or in parallel with ordinary reservoirs.The design of partitions and the holes on them are analyzed.How to layout the manholes and integration with overflow and ventilation facilities is also proposed.%针对水处理构筑物下叠清水池节省占地面积的特点,浅析了下叠清水池的设计要点,提出串联与并联的下叠清水池不同水位的确定方式.探讨了下叠清水池的隔墙及隔墙上各孔洞的设计细节,分析了下叠清水池人孔的布置形式与设置位置.建议尽可能将溢流设施、通风装置与人孔合建,最大限度降低清水池漏水风险,方便施工与运行.