Objective: To evaluate the efficacy of double-phase contrast material-enhanced computed tomography (CT) in assessing no-surgical treatment response in bronchogenic carcinoma preliminarily. Methods: 52 patients with bronchogenic carcinoma after no-surgical treatment underwent double-phase contrast material-enhanced computed tomography. Two spiral CT scans were obtained at 25 and 90 seconds respectively after nonionic contrast material was administrated via the antecubital vein at a rate of 4 mL/s by using an autoinjector. Precontrast and postcontrast attenuation on every scan was recorded and peak height was calculated. Enhancement pattern was evaluated on the images obtained at 25 and 90 seconds after injection of contrast medium. Results: Precontrast attenuation, postcontrast attenuation at 25 and 90 seconds were 42.20±7.43 Hu, 57.35 ± 10.09 Hu and 71.85 ± 12.45 Hu, respectively. No statistically significant difference in precontrast attenuation was found between our results in the study and the results in our old study (mean precontrast attenuation 40.70 Hu) which was obtained in cases before therapy (t = 1.455, P = 0.152 > 0.05). Peak height of bronchogenic carcinoma after no-surgical treatment (29.46 ± 10.85 Hu) were significantly lower than that of bronchogenic carcinoma before therapy obtained in our old study (mean peak height 35.79 Hu; t = 4.206, P = 0.001 < 0.05). 32 of 52 cases showed homogeneous enhancement at 90 seconds. Of the 32 cases, there were 21 with inhomogeneous enhancement, 7 with inhomogeneous enhancement, 2 with central enhancement and 2 with peripheral enhancement at 25 seconds. Conclusion: Bronchogenic carcinoma after no-surgical treatment shows a gradual increase to the peak height after administration of contrast material. Peak heights can reflect the blood supply of bronchogenic carcinoma and might be index for evaluation of no-surgical treatment response in bronchogenic carcinoma.
机译:目的:评价双相造影材料增强的计算机断层扫描(CT)初步评估支气管生成癌中的无手术治疗响应的疗效。方法:52例支气管内癌患者在无手术治疗后进行双相造影材料增强的计算断层扫描。通过使用自动注射器以4mL / s的速率通过抗腊肠静脉通过抗腊肠静脉施用非离子造影剂在25和90秒下获得两种螺旋CT扫描。记录每次扫描的预体和后波动衰减,并计算峰值高度。在注射造影剂后在25和90秒获得的图像上评估增强模式。结果:预体衰减,25秒和90秒的后期衰减分别为42.20±7.43胡,分别为57.35±10.09胡,分别为71.85±12.45胡胡。在我们在治疗前的病例中获得的研究结果,在研究中没有统计学意义的预衰减差异在研究中,结果(平均预体衰减40.70U)(t = 1.455,p = 0.152> 0.05)。在我们旧研究中获得的治疗前(29.46±10.85UU)在无手术治疗后的支气管生成癌的峰高(29.46±10.85u)(平均峰值高度35.79u; t = 4.206,p = 0.001 <0.05)。 32例52例均显示均匀增强90秒。在32例中,21例具有21个具有不均匀的增强,7例,具有不均匀的增强,2例,2例,中枢增强和22例,2例25秒,25秒内提高。结论:无手术治疗后的支气管生成癌显示出造影材料后逐渐增加到峰值高度。峰值高度可以反映支气管生成癌的血液供应,并且可能是在支气管生成癌中评估无手术治疗反应的指标。

著录项

  • 来源
    《中德临床肿瘤学杂志(英文版)》 |2009年第003期|152-155|共4页
  • 作者单位

    Department of Imageology The Eighty-eighth Military Hospital Tai'an 271000 China;

    Department of Imageology The Eighty-eighth Military Hospital Tai'an 271000 China;

    Department of Imageology The Eighty-eighth Military Hospital Tai'an 271000 China;

    Department of Imageology The Eighty-eighth Military Hospital Tai'an 271000 China;

    Department of Imageology The Eighty-eighth Military Hospital Tai'an 271000 China;

    Department of Imageology The Eighty-eighth Military Hospital Tai'an 271000 China;

    Department of Imageology The Eighty-eighth Military Hospital Tai'an 271000 China;

    Department of Imageology The Eighty-eighth Military Hospital Tai'an 271000 China;

  • 收录信息 中国科技论文与引文数据库(CSTPCD);
  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 肿瘤学;
  • 关键词

  • 入库时间 2022-08-19 04:48:21
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号