首页> 外文期刊>等离子体科学和技术(英文版) >Conceptual design and heat transfer performance of a flat-tile water-cooled divertor target
【24h】

Conceptual design and heat transfer performance of a flat-tile water-cooled divertor target

机译:扁平瓷砖水冷偏移靶的概念设计和传热性能

获取原文
获取原文并翻译 | 示例
       

摘要

The divertor target components for the Chinese fusion engineering test reactor(CFETR)and the future experimental advanced superconducting tokamak(EAST)need to remove a heat flux of up to20 MW m-2.In view of such a high heat flux removal requirement,this study proposes a conceptual design for a flat-tile divertor target based on explosive welding and brazing technology.Rectangular water-cooled channels with a special thermal transfer structure(TTS)are designed in the heat sink to improve the flat-tile divertor target’s heat transfer performance(HTP).The parametric design and optimization methods are applied to study the influence of the TTS variation parameters,including height(H),width(W*),thickness(T),and spacing(L),on the HTP.The research results show that the flat-tile divertor target’s HTP is sensitive to the TTS parameter changes,and the sensitivity is T>L>W*>H.The HTP first increases and then decreases with the increase of T,L,and W*and gradually increases with the increase of H.The optimal design parameters are as follows:H=5.5 mm,W*=25.8 mm,T=2.2 mm,and L=9.7 mm.The HTP of the optimized flat-tile divertor target at different flow speeds and tungsten tile thicknesses is studied using the numerical simulation method.A flat-tile divertor mock-up is developed according to the optimized parameters.In addition,high heat flux(HHF)tests are performed on an electron beam facility to further investigate the mock-up HTP.The numerical simulation calculation results show that the optimized flat-tile divertor target has great potential for handling the steady-state heat load of 20 MW m-2under the tungsten tile thickness<5 mm and the flow speed7 m s^(-1).The heat transfer efficiency of the flat-tile divertor target with rectangular cooling channels improves by13%and30%compared to that of the flat-tile divertor target with circular cooling channels and the ITER-like monoblock,respectively.The HHF tests indicate that the flat-tile divertor mock-up can successfully withstand 1000 cycles of20 MW m-2of heat load without visible deformation,damage,and HTP degradation.The surface temperature of the flat-tile divertor mock-up at the 1000th cycle is only930℃.The flat-tile divertor target’s HTP is greatly improved by the parametric design and optimization method,and is better than the ITER-like monoblock and the flat-tile mock-up for the WEST divertor.This conceptual design is currently being applied to the engineering design of the CFETR and EAST flat-tile divertors.

著录项

  • 来源
    《等离子体科学和技术(英文版)》 |2021年第9期|194-205|共12页
  • 作者单位

    Institute of Plasma Physics Chinese Academy of Sciences Hefei 230031 People's Republic of China;

    Institute of Plasma Physics Chinese Academy of Sciences Hefei 230031 People's Republic of China;

    Institute of Plasma Physics Chinese Academy of Sciences Hefei 230031 People's Republic of China;

    Institute of Plasma Physics Chinese Academy of Sciences Hefei 230031 People's Republic of China;

    Institute of Plasma Physics Chinese Academy of Sciences Hefei 230031 People's Republic of China;

    Institute of Plasma Physics Chinese Academy of Sciences Hefei 230031 People's Republic of China;

    Institute of Plasma Physics Chinese Academy of Sciences Hefei 230031 People's Republic of China;

    Institute of Plasma Physics Chinese Academy of Sciences Hefei 230031 People's Republic of China;