H_α/ D_α Measurements Based on Photo Diode Array in the HT-7 Tokamak

         

摘要

Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is convenient to be arranged in experiment. With the PDA system, the particle confinement time (τp) has been systematically investigated. The relations such as τp on the center-line-averaged electron density (ne), τp on plasma current (Ip), and τp, on the toroidal magnetic field (Bt) have been obtained. The particle confinement under the Ion Berstain Wave (IBW) Heating has also been measured and analyzed.