首页> 外文期刊>核技术(英文版) >Baseline recovery method to measure bunch charge under low-current mode of SSRF
【24h】

Baseline recovery method to measure bunch charge under low-current mode of SSRF

机译:SSRF低电流模式下用于测量束电荷的基线恢复方法

获取原文
获取原文并翻译 | 示例
       

摘要

The top-up injection mode of Shanghai Synchrotron Radiation Facility(SSRF) needs precise measurement of the beam bunch charges.This is performed by an integration current transformer,but the beam current is too low to neglect the background noise.In order to wipe out the noise coming from the ground loops,the adaptable polynomial fitting method is used to extract the baseline,instead of using the constant background or the linear background model. Test results show that the system resolution can be improved to <3%.

著录项

  • 来源
    《核技术(英文版)》 |2011年第5期|261-264|共4页
  • 作者单位

    Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Shanghai 201800, China;

    Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Shanghai 201800, China;

    Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Shanghai 201800, China;

    Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Shanghai 201800, China;

    Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Shanghai 201800, China;

  • 收录信息 中国科学引文数据库(CSCD);
  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

  • 入库时间 2022-08-19 03:36:56
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号