A bionic fish cilia median-low frequency three-dimensional MEMS vector hydrophone is reported in this paper. The piezoresistive reasonable position was obtained through finite element analysis by ANSYS and the structure was formed by MEMS processes including lithography, ion implantation, PECVD and etching,etc. The standing wave barrel results show that the lowest sensitivity of the hydrophone is-200 d B and reach up to-160 d B(in which the voltage amplification factor is 300). It has a good frequency response characteristics in 25 Hz ~ 1500 Hz band. Directivity tests displayed that the hydrophone has a good '8'-shaped directivity,in which the resolution is not less than 30 d B, and asymmetry of the maximum axial sensitivity value is less than 1.2 d B.
机译:本文报道了仿生鱼纤毛中低频三维MEMS矢量水听器。通过ANSYS有限元分析获得压阻合理位置,并通过光刻,离子注入,PECVD和刻蚀等MEMS工艺形成结构。驻波桶结果表明,水听器的最低灵敏度为-200 d B,最高可达-160 d B(其中电压放大系数为300)。在25 Hz〜1500 Hz频段具有良好的频率响应特性。方向性测试表明,水听器具有良好的“ 8”形方向性,其分辨率不小于30 d B,最大轴向灵敏度值的不对称性小于1.2 dB。

著录项

  • 来源
    《纳微快报:英文版》 |2014年第002期|P.136-142|共7页
  • 作者单位

    School of Marine Science and Technology,Northwestern Polytechnical University;

    Key Laboratory of Instrumentation Science & Dynamic Measurement,Ministry of Education,North University of China;

    Key Laboratory of Science and Technology on Electronic Test & Measurement,North University of China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 CHI
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号